Hypercrosslinked polystyrene as a novel type of high-performance liquid chromatography column packing material - Mechanisms of retention

被引:61
作者
Davankov, V
Sychov, CS
Ilyin, MM
Sochilina, KO
机构
[1] Inst Organoelement Cpds, Moscow 119991, Russia
[2] Purolite Int, Pontyclun CF7 8YL, Wales
关键词
stationary phases; LQ retention mechanism; principal component analysis; polystyrene stationary phases;
D O I
10.1016/S0021-9673(02)01914-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An experimental material, Chromalite 5HGN (Purolite, UK), that represents hypercrosslinked polystyrene as a new type of neutral stationary phase for HPLC was examined. The material contains no functional groups, but is compatible with any kind of nonpolar and highly polar mobile phase, and even with water. It is chemically resistant and thermally stable. When using aqueous organic mobile phases, Chromalite 5HGN works similar to standard C-18 reversed-phase packings, but is characterized by much greater hydrophobicity and, sometimes, unusual selectivity. When using nonpolar mobile phases, i.e. under "quasi normal-phase" conditions, the retention is mostly governed by the interactions between pi-electronic systems of the adsorbent and adsorbate. Adding highly polar, even hydrophilic solvents into the mobile phase, leads to a shift of retention times toward the "reversed-phase" kind of chromatography, which gives an additional possibility in fine tuning the column selectivity. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:67 / 75
页数:9
相关论文
共 18 条
[1]   High-performance liquid chromatography with non-aqueous solvents - Relative elution strength on a polystyrene-divinylbenzene column [J].
Chambers, TK ;
Fritz, JS .
JOURNAL OF CHROMATOGRAPHY A, 1996, 728 (1-2) :271-278
[2]   Effect of polystyrene-divinylbenzene resin sulfonation on solute retention in high-performance liquid chromatography [J].
Chambers, TK ;
Fritz, JS .
JOURNAL OF CHROMATOGRAPHY A, 1998, 797 (1-2) :139-147
[3]   Hypercross-linked polystyrene and its potentials for liquid chromatography: a mini-review [J].
Davankov, V ;
Tsyurupa, M ;
Ilyin, M ;
Pavlova, L .
JOURNAL OF CHROMATOGRAPHY A, 2002, 965 (1-2) :65-73
[4]   STRUCTURE AND PROPERTIES OF HYPERCROSSLINKED POLYSTYRENE - THE 1ST REPRESENTATIVE OF A NEW CLASS OF POLYMER NETWORKS [J].
DAVANKOV, VA ;
TSYURUPA, MP .
REACTIVE POLYMERS, 1990, 13 (1-2) :27-42
[5]   Retention parameters in chromatography (IUPAC recommendations 2001) [J].
Domínguez, JAG ;
Díez-Masa, JC ;
Davankov, VA .
PURE AND APPLIED CHEMISTRY, 2001, 73 (06) :969-992
[6]   Simultaneous separation and quantitation of the major bovine whey proteins including proteose peptone and caseinomacropeptide by reversed-phase high-performance liquid chromatography on polystyrene-divinylbenzene [J].
Elgar, DF ;
Norris, CS ;
Ayers, JS ;
Pritchard, M ;
Otter, DE ;
Palmano, KP .
JOURNAL OF CHROMATOGRAPHY A, 2000, 878 (02) :183-196
[7]   Use of principal component analysis for studying the separation of pesticides on polyethylene-coated silica columns [J].
Forgács, E ;
Cserháti, T .
JOURNAL OF CHROMATOGRAPHY A, 1998, 797 (1-2) :33-39
[8]   Consolidation and column performance of several packing materials for liquid chromatography in a dynamic axial compression column [J].
Koh, JH ;
Broyles, BS ;
Guan-Sajonz, H ;
Hu, MZC ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 1998, 813 (02) :223-238
[9]   Organic modifiers for the separation of organic acids and bases by liquid chromatography [J].
Li, S ;
Fritz, JS .
JOURNAL OF CHROMATOGRAPHY A, 2002, 964 (1-2) :91-98
[10]   Comparison of methods for characterization of reversed-phase liquid chromatographic selectivity [J].
Lopez, LA ;
Rutan, SC .
JOURNAL OF CHROMATOGRAPHY A, 2002, 965 (1-2) :301-314