Mold and endotoxin levels in the aftermath of Hurricane Katrina: A pilot project of homes in New Orleans undergoing renovation

被引:83
作者
Chew, Ginger L.
Wilson, Jonathan
Rabito, Felicia A.
Grimsley, Faye
Iqbal, Shahed
Reponen, Tiina
Muilenberg, Michael L.
Thorne, Peter S.
Dearborn, Dorr G.
Morley, Rebecca L.
机构
[1] Columbia Univ, Mailman Sch Publ Hlth, Dept Environm Hlth Sci, New York, NY 10032 USA
[2] Natl Ctr Healthy Housing, Columbia, MD USA
[3] Tulane Sch Publ Hlth & Trop Med, Dept Epidemiol, New Orleans, LA USA
[4] Tulane Sch Publ Hlth & Trop Med, Dept Environm Hlth, New Orleans, LA USA
[5] Univ Cincinnati, Dept Environm Hlth, Cincinnati, OH USA
[6] Harvard Univ, Sch Publ Hlth, Dept Environm Hlth, Boston, MA 02115 USA
[7] Univ Iowa, Coll Publ Hlth, Dept Environm & Occupat Hlth, Iowa City, IA USA
[8] Case Western Reserve Univ, Dept Environm Hlth Sci, Cleveland, OH 44106 USA
关键词
endotoxin; flood; fungi; mold; Hurricane Katrina; New Orleans; remediation; respirators;
D O I
10.1289/ehp.9258
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
BACKGROUND: After Hurricane Katrina, many New Orleans homes remained flooded for weeks, promoting heavy microbial growth. OBJECTIVES: A small demonstration project was conducted November 2005-January 2006 aiming to recommend safe remediation techniques and safe levels of worker protection, and to characterize airborne mold and endotoxin throughout cleanup. METHODS: Three houses with floodwater lines between 0.3 and 2 m underwent intervention, including disposal of damaged furnishings and drywall, cleaning surfaces, drying remaining structure, and treatment with a biostatic agent. We measured indoor and outdoor bioaerosols before, during, and after intervention. Samples were analyzed for fungi [culture, spore analysis, polymerase chain reaction (PCR)] and endotoxin. In one house, real-time particle counts were also assessed, and respirator-efficiency testing was performed to establish workplace protection factors (WPF). RESULTS: At baseline, culturable mold ranged from 22,000 to 515,000 colony-forming units/m(3), spore counts ranged from 82,000 to 630,000 spores/m(3), and endotoxin ranged from 17 to 139 endotoxin units/m3. Culture, spore analysis, and PCR indicated that Penicillium, Aspetyillus, and Paecilomyces predominated. After intervention, levels of mold and endotoxin were generally lower (sometimes, orders of magnitude). The average WPF against fungal spores for elastomeric respirators was higher than for the N-95 respirators. CONCLUSIONS: During baseline and intervention, mold and endotoxin levels were similar to those found in agricultural environments. We strongly recommend that those entering, cleaning, and repairing flood-damaged homes wear respirators at least as protective as elastomeric respirators. Recommendations based on this demonstration will benefit those involved in the current cleanup activities and will inform efforts to respond to future disasters.
引用
收藏
页码:1883 / 1889
页数:7
相关论文
共 39 条
[1]   Performance of the Button Personal Inhalable Sampler for the measurement of outdoor aeroallergens [J].
Adhikari, A ;
Martuzevicius, D ;
Reponen, T ;
Grinshpun, SA ;
Cho, SH ;
Sivasubramani, SK ;
Zhong, W ;
Levin, L ;
Kelley, AL ;
St Clair, HG ;
Lemastersa, G .
ATMOSPHERIC ENVIRONMENT, 2003, 37 (34) :4723-4733
[2]  
*AM RED CROSS FED, 1992, 4476 ARC FEMA
[3]   Manikin-based performance evaluation of N95 filtering-facepiece respirators challenged with nanoparticles [J].
Balazy, A ;
Toivola, M ;
Reponen, T ;
Podgo,rski, A ;
Zimmer, A ;
Grinshpun, SA .
ANNALS OF OCCUPATIONAL HYGIENE, 2006, 50 (03) :259-269
[4]  
*CDC, 2005, MOLD PREV STRAT POSS
[5]   Allergenic proteins are fragmented in low concentrations of sodium hypochlorite [J].
Chen, P ;
Eggleston, PA .
CLINICAL AND EXPERIMENTAL ALLERGY, 2001, 31 (07) :1086-1093
[6]   Dustborne and airborne fungal propagules represent a different spectrum of fungi with differing relations to home characteristics [J].
Chew, GL ;
Rogers, C ;
Burge, HA ;
Muilenberg, ML ;
Gold, DR .
ALLERGY, 2003, 58 (01) :13-20
[7]   Fungal extracellular polysaccharides, β (1→3)-glucans and culturable fungi in repeated sampling of house dust [J].
Chew, GL ;
Douwes, J ;
Doekes, G ;
Higgins, KM ;
van Strien, R ;
Spithoven, J ;
Brunekreef, B .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 2001, 11 (03) :171-178
[8]   AIRBORNE ENDOTOXIN CONCENTRATIONS IN VARIOUS WORK AREAS WITHIN A COTTON MILL IN CENTRAL-AMERICA [J].
CHRISTIANI, DC ;
VELAZQUEZ, A ;
WILCOX, M ;
OLENCHOCK, SA .
ENVIRONMENTAL RESEARCH, 1993, 60 (02) :187-192
[9]   Bioaerosol health effects and exposure assessment: Progress and prospects [J].
Douwes, J ;
Thorne, P ;
Pearce, N ;
Heederik, D .
ANNALS OF OCCUPATIONAL HYGIENE, 2003, 47 (03) :187-200
[10]   A comparison of airborne ergosterol, glucan and Air-O-Cell data in relation to physical assessments of mold damage and some other parameters [J].
Foto, M ;
Vrijmoed, LLP ;
Miller, JD ;
Ruest, K ;
Lawton, M ;
Dales, RE .
INDOOR AIR, 2005, 15 (04) :257-266