Allergologically relevant rubber accelerators in single-use medical gloves

被引:52
作者
Knudsen, BB
Hametner, C
Seycek, O
Heese, A
Koch, HU
Peters, KP
机构
[1] Gentofte Univ Hosp, Dept Dermatol, Copenhagen, Denmark
[2] Ostereich Inst Biomed Werkstofftech, Vienna, Austria
[3] Univ Erlangen Nurnberg, Dermatol Klin, Erlangen, Germany
关键词
natural rubber latex; medical gloves; rubber accelerators; chemical analysis; extraction procedures; ingredient information; clinical relevance;
D O I
10.1034/j.1600-0536.2000.043001009.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
To prevent contact with specific rubber accelerators, sensitized patients have to know in which glove brands these accelerators are present. Additionally, quantitative measurements of the bioavailable amounts of accelerators are needed to assist consumers in selecting gloves with the lowest possible amount of residual rubber accelerators. The aim of the study was to develop an analytical method by which residuals of rubber accelerators in single-use medical gloves could be determined qualitatively and quantitatively. 19 different glove brands were analysed for content of accelerators, and the results were compared to manufacturers' ingredient claims of the identical gloves. ZDEC, ZDBC, ZMBT and ZPC were the most frequently detected chemicals. In 9 of 15 gloves discrepancies were found, usually minor, between content of accelerators declared by manufacturers to be present and accelerators detected by analysis. Both phosphate buffer and acetone were tested as extraction media. No accelerators were detectable with the described chemical analysis in phosphate extracts, whereas acetone was demonstrated to be a technically suitable medium for extraction. However, more kinetic studies of the extraction procedure and studies of skin penetration are needed to document that the extraction procedure simulates the clinical situation.
引用
收藏
页码:9 / 15
页数:7
相关论文
共 25 条
[1]  
*COMM EUR COMM MEA, 1998, MAT1CT940060 COMM EU
[2]  
Cronin E., 1980, CONTACT DERMATITIS, P714
[3]  
*DIN, 1994, 32645 DIN
[4]   SKIN ELICITATION THRESHOLD OF ETHYLBUTYL THIOUREA AND MERCAPTOBENZOTHIAZOLE WITH RELATIVE LEACHING FROM SENSITIZING PRODUCTS [J].
EMMETT, EA ;
RISBY, TH ;
TAYLOR, J ;
CHEN, CL ;
JIANG, L ;
FEINMAN, SE .
CONTACT DERMATITIS, 1994, 30 (02) :85-90
[5]   ALLERGIC CONTACT-DERMATITIS TO NICKEL - BIOAVAILABILITY FROM CONSUMER PRODUCTS AND PROVOCATION THRESHOLD [J].
EMMETT, EA ;
RISBY, TH ;
JIANG, L ;
SEE, KN ;
FEINMAN, S .
JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1988, 19 (02) :314-322
[6]  
*EN, 1998, 4553 EN
[7]  
ESTLANDER T, 1994, PROTECTIVE GLOVES OC, P221
[8]  
FRANCK R, 1998, KUNSTSTOFFE LEBENS S, V48
[9]  
HalkierSorensen L, 1996, CONTACT DERMATITIS, V35, pR3
[10]   ALLERGIC AND IRRITANT REACTIONS TO RUBBER GLOVES IN MEDICAL HEALTH-SERVICES - SPECTRUM, DIAGNOSTIC-APPROACH, AND THERAPY [J].
HEESE, A ;
VONHINTZENSTERN, J ;
PETERS, KP ;
KOCH, HU ;
HORNSTEIN, OP .
JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1991, 25 (05) :831-839