Nafion-PAN optical chemical sensor: optimization by FIA

被引:14
作者
Coo, LD
Belmonte, CJ
机构
[1] Univ Philippines, Inst Chem, Quezon City 1101, Philippines
[2] Univ Philippines, Nat Sci Res Inst, Quezon City 1101, Philippines
关键词
spectrophotometer; chemical sensor; optrode system;
D O I
10.1016/S0039-9140(02)00429-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A copper-sensitive optical chemical sensor (optrode) is described. The optrode is based on a Nafion membrane and an immobilized organic ligand coupled with a flow injection (FI) system. The FI system includes a flow-through removable measuring cell and a simple spectrophotometer. Owing to the miniature size of the system and the efficient use of optical fibers, this optrode is well suited for monitoring environmental water samples. The success of the described optrode system depends on the effectiveness of the FI reagent delivery system. Optimum contact time with the membrane (as determined by the reagent flow rates) and the injected sample volume are critical. Environmental water samples were analyzed for copper content using the optimized optrode system. To validate the optrode's performance, the same water samples were analyzed using the atomic absorption spectrophotometer. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1063 / 1069
页数:7
相关论文
共 15 条
[1]   SYNTHESIS AND CHARACTERIZATION OF NEUTRAL HYDROGEN ION-SELECTIVE CHROMOIONOPHORES FOR USE IN BULK OPTODES [J].
BAKKER, E ;
LERCHI, M ;
ROSATZIN, T ;
RUSTERHOLZ, B ;
SIMON, W .
ANALYTICA CHIMICA ACTA, 1993, 278 (02) :211-225
[2]   Study of the extraction of 1-(2′-pyridylazo)-2-naphthol from ethanol-water solutions into Nafion® membranes [J].
Coo, LD ;
Cardwell, TJ ;
Cattrall, RW ;
Kolev, SD .
ANALYTICA CHIMICA ACTA, 1999, 392 (2-3) :201-211
[3]  
COO LD, 1999, P 15 AUSTR AN CHEM C
[4]  
*DENR EMB, 2000, ANN REP
[5]   Recent advances in perfluorinated ionomer membranes: Structure, properties and applications [J].
HeitnerWirguin, C .
JOURNAL OF MEMBRANE SCIENCE, 1996, 120 (01) :1-33
[6]   FIBEROPTIC POTASSIUM-ION SENSOR USING ALKYL-ACRIDINE ORANGE IN PLASTICIZED POLY(VINYL CHLORIDE) MEMBRANE [J].
KAWABATA, Y ;
TAHARA, R ;
KAMICHIKA, T ;
IMASAKA, T ;
ISHIBASHI, N .
ANALYTICAL CHEMISTRY, 1990, 62 (14) :1528-1531
[7]  
Kipling B., 1982, ACS SYM SER, V180
[8]   LEAD-SELECTIVE BULK OPTODES BASED ON NEUTRAL IONOPHORES WITH SUBNANOMOLAR DETECTION LIMITS [J].
LERCHI, M ;
BAKKER, E ;
RUSTERHOLZ, B ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1992, 64 (14) :1534-1540
[9]   Nafion-based optode for the detection of metal ions in flow analysis [J].
Madden, JE ;
Cardwell, TJ ;
Cattrall, R ;
Deady, LW .
ANALYTICA CHIMICA ACTA, 1996, 319 (1-2) :129-134
[10]   DESIGN OF A CALCIUM-SELECTIVE OPTODE MEMBRANE BASED ON NEUTRAL IONOPHORES [J].
MORF, WE ;
SEILER, K ;
RUSTERHOLZ, B ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1990, 62 (07) :738-742