Computer-simulated radiation dose reduction for abdominal multidetector CT of pediatric patients

被引:140
作者
Frush, DP
Slack, CC
Hollingsworth, CL
Bisset, GS
Donnelly, LF
Hsieh, J
Lavin-Wensell, T
Mayo, JR
机构
[1] Duke Univ, Med Ctr, McGovern Davison Childrens Hlth Ctr 1905, Dept Radiol,Div Pediat Radiol, Durham, NC 22710 USA
[2] GE Co, Med Syst, Waukesha, WI 53188 USA
[3] Childrens Hosp & Med Ctr, Dept Radiol, Cincinnati, OH 45229 USA
[4] Univ British Columbia, Dept Radiol, Vancouver, BC V5Z 1M9, Canada
[5] Univ British Columbia, Vancouver Hosp & Hlth Sci Ctr, Vancouver, BC V5Z 1M9, Canada
关键词
D O I
10.2214/ajr.179.5.1791107
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Limiting CT radiation dose is especially critical when imaging children. The purpose of our study was to modify and test an accurate and safe tool for evaluating systematic dose reduction for abdominal multidetector CT (MDCT) in pediatric patients. MATERIALS AND METHODS. After validating the computer-simulation technique with a water phantom, we subjected the original digital scanning data for 26 contrast-enhanced abdominal MDCT scans (120 mA) obtained in infants and children (age range, I month-9 years; mean age, 3.1 years) to simulated tube current reduction (100, 80, 60, and 40 mA) by adding noise. This procedure created four additional examinations per child that were identical to the originals except for image noise. The 130 examinations were scored randomly, independently, and without prior knowledge of the children's diagnoses by three radiologists for depiction of high-visibility structures, such as adrenal glands and fat in the intrahepatic falciform ligament, and low-visibility structures, such as the extrahepatic hepatic artery, small intrahepatic vessels, and common bile duct. Aligned rank and Wilcoxon's signed rank tests were used for statistical analyses. RESULTS. Simulated tube current reduction significantly affected the detection of low-visibility structures (p < 0.001). Reduced detection in low-visibility structures was evident at a level less than or equal to 80 mA. No loss of detection in high-visibility structures was found at any tube current level (p > 0.5). CONCLUSION. The results of this computer simulation suggest that accurate abdominal MDCT can be performed in pediatric patients using substantially reduced radiation, depending on the indication for imaging. (In our case, the reduction was between 33% and 67%, depending on whether a high-visibility or low-visibility structure was being assessed.) This simulation technology can be applied to MDCT of other organ systems for systematic evaluation of radiation dose reduction.
引用
收藏
页码:1107 / 1113
页数:7
相关论文
共 18 条
[1]   FEASIBILITY OF HIGH-RESOLUTION, LOW-DOSE CHEST CT IN EVALUATING THE PEDIATRIC CHEST [J].
AMBROSINO, MM ;
GENIESER, NB ;
ROCHE, KJ ;
KAUL, A ;
LAWRENCE, RM .
PEDIATRIC RADIOLOGY, 1994, 24 (01) :6-10
[2]   APPLICATION OF THIN-SECTION LOW-DOSE CHEST CT (TSCT) IN THE MANAGEMENT OF PEDIATRIC AIDS [J].
AMBROSINO, MM ;
ROCHE, KJ ;
GENIESER, NB ;
KAUL, A ;
LAWRENCE, RM .
PEDIATRIC RADIOLOGY, 1995, 25 (05) :393-400
[3]   Estimated risks of radiation-induced fatal cancer from pediatric CT [J].
Brenner, DJ ;
Elliston, CD ;
Hall, EJ ;
Berdon, WE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :289-296
[4]   Fallout from recent articles on radiation dose and pediatric CT [J].
Donnelly, LF ;
Frush, DP .
PEDIATRIC RADIOLOGY, 2001, 31 (06) :388-388
[5]   Minimizing radiation dose for pediatric body applications of single-detector helical CT: Strategies at a large children's hospital [J].
Donnelly, LF ;
Emery, KH ;
Brody, AS ;
Laor, T ;
Gylys-Morin, VM ;
Anton, CG ;
Thomas, SR ;
Frush, DP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :303-306
[6]   Helical CT in children: Technical considerations and body applications [J].
Frush, DP ;
Donnelly, LF .
RADIOLOGY, 1998, 209 (01) :37-48
[7]   Image quality and dose in computed tomography [J].
Jurik, AG ;
Jessen, KA ;
Hansen, J .
EUROPEAN RADIOLOGY, 1997, 7 (01) :77-81
[8]   RADIATION-DOSE REDUCTION IN CT OF THE PEDIATRIC PELVIS [J].
KAMEL, IR ;
HERNANDEZ, RJ ;
MARTIN, JE ;
SCHLESINGER, AE ;
NIKLASON, LT ;
GUIRE, KE .
RADIOLOGY, 1994, 190 (03) :683-687
[9]   Low-dose high-resolution CT of the chest in children and young adults:: Dose, cooperation, artifact incidence, and image quality [J].
Lucaya, J ;
Piqueras, J ;
García-Peña, P ;
Enríquez, G ;
García-Macías, M ;
Sotil, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (04) :985-992
[10]   Simulated dose reduction in conventional chest CT: Validation study [J].
Mayo, JR ;
Whittall, KP ;
Leung, AN ;
Hartman, TE ;
Park, CS ;
Primack, SL ;
Chambers, GK ;
Limkeman, MK ;
Toth, TL ;
Fox, SH .
RADIOLOGY, 1997, 202 (02) :453-457