Biomechanical Characteristics of Different Regions of the Human Spine An In Vitro Study on Multilevel Spinal Segments

被引:98
作者
Busscher, Iris [1 ]
van Dieen, Jaap H. [2 ]
Kingma, Idsart [2 ]
van der Veen, Albert J. [3 ]
Verkerke, Gijsbertus J. [4 ,5 ]
Veldhuizen, Albert G. [1 ]
机构
[1] Univ Groningen, Dept Orthopaed, Univ Med Ctr Groningen, NL-9713 GZ Groningen, Netherlands
[2] Vrije Univ Amsterdam, Dept Human Movement Sci, Res Inst MOVE, Amsterdam, Netherlands
[3] Vrije Univ Amsterdam, Dept Phys & Med Technol, Res Inst MOVE, Med Ctr, Amsterdam, Netherlands
[4] Univ Groningen, Dept Biomed Engn, Univ Med Ctr Groningen, NL-9713 GZ Groningen, Netherlands
[5] Univ Twente, Dept Biomech Engn, NL-7500 AE Enschede, Netherlands
关键词
thoracolumbar spine; in vitro; biomechanics; motion segment; range of motion; neutral zone; stiffness; THORACOLUMBAR SPINE; MOTION SEGMENTS; LUMBAR SPINE; 3-DIMENSIONAL FLEXIBILITY; THORACIC SPINE; NEUTRAL ZONE; BEHAVIOR; SPECIMENS; PRELOAD; SYSTEM;
D O I
10.1097/BRS.0b013e3181b4c75d
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
Study Design. An in vitro study on human multilevel spinal segments. Objective. To determine the differences in biomechanical characteristics between 4 separate regions of the human spine and to provide quantitative information is derived on the range of motion (ROM), neutral zone (NZ), neutral zone stiffness (NZstiff), and flexibility (FLEX). Summary of Background Data. Limited literature is available about the biomechanical behavior of different regions of the human spine, in particular with multilevel segments. Test setup en protocols were different between studies and therefore outcomes of separate regions are hardly comparable. Methods. A total of 24 spinal segments of 6 human cadaveric spines were prepared for biomechanical testing. Each specimen contained 4 vertebrae and 3 intervertebral discs: T1-T4, T5-T8, T9-T12, and L1-L4. Pure moments were applied to a maximum of 4 Nm in flexion/extension, lateral bending, and axial rotation. Displacement of individual motion segments was measured using a 3-dimensional movement registration system. ROM, NZ, NZstiff, and FLEX of the spinal regions were calculated from the acquired load-displacement data. Results. In axial direction, ROM and NZ decreased and NZ stiffness increased from high to low vertebral levels. For flexion/extension and lateral flexion highest ROM and NZ and lowest NZ stiffness values were found at the T1-T4 and L1-L4 regions. NZ magnitudes and NZ stiffnesses were negatively correlated (P < 0.05). Flexibility of the spinal regions was variable; no significant differences were found between the 4 spinal regions. Conclusion. This study showed the differences in ROM, NZ, and NZ stiffness between thoracolumbar regions of the human spine in axial rotation, flexion/extension, and lateral bending. Separate multilevel spinal segments were tested in 1 study, and therefore characteristics of different regions are truly comparable.
引用
收藏
页码:2858 / 2864
页数:7
相关论文
共 26 条
[1]
The dynamic flexion/extension properties of the lumbar spine in vitro using a novel pendulum system [J].
Crisco, Joseph J. ;
Fujita, Lindsey ;
Spenciner, David B. .
JOURNAL OF BIOMECHANICS, 2007, 40 (12) :2767-2773
[2]
Effect of specimen length: are the mechanics of individual motion segments comparable in functional spinal units and multisegment specimens? [J].
Dickey, JP ;
Kerr, DJ .
MEDICAL ENGINEERING & PHYSICS, 2003, 25 (03) :221-227
[3]
Structural behavior of human lumbar spinal motion segments [J].
Gardner-Morse, MG ;
Stokes, IAF .
JOURNAL OF BIOMECHANICS, 2004, 37 (02) :205-212
[4]
The effect of loading rate and degeneration on neutral region motion in human cadaveric lumbar motion segments [J].
Gay, Ralph E. ;
Ilharreborde, Brice ;
Zhao, Kristin ;
Bournediene, Emir ;
An, Kai-Nan .
CLINICAL BIOMECHANICS, 2008, 23 (01) :1-7
[5]
Sagittal plane motion in the human lumbar spine: Comparison of the in vitro quasistatic neutral zone and dynamic motion parameters [J].
Gay, Ralph E. ;
Ilharreborde, Brice ;
Zhao, Kristin ;
Zhao, Chunfeng ;
An, Kai-Nan .
CLINICAL BIOMECHANICS, 2006, 21 (09) :914-919
[6]
Test protocols for evaluation of spinal implants [J].
Goel, VK ;
Panjabi, MM ;
Patwardhan, AG ;
Dooris, AP ;
Serhan, H .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A :103-109
[7]
Moment-rotation responses of the human lumbosacral spinal column [J].
Guan, Yabo ;
Yoganandan, Narayan ;
Moore, Jason ;
Pintar, Frank A. ;
Zhang, Jiangyue ;
Maiman, Dennis J. ;
Laud, Purushottam .
JOURNAL OF BIOMECHANICS, 2007, 40 (09) :1975-1980
[8]
Three-dimensional measurement of intervertebral kinematics in vitro using optical motion analysis [J].
Holt, CA ;
Evans, SL ;
Dillon, D ;
Ahuja, S .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2005, 219 (H6) :393-399
[9]
A continuous pure moment loading apparatus for biomechanical testing of multi-segment spine specimens [J].
Lysack, JT ;
Dickey, JP ;
Dumas, GA ;
Yen, D .
JOURNAL OF BIOMECHANICS, 2000, 33 (06) :765-770
[10]
Facet orientation in the thoracolumbar spine - Three-dimensional anatomic and biomechanical analysis [J].
Masharawi, Y ;
Rothschild, B ;
Dar, G ;
Peleg, S ;
Robinson, D ;
Been, E ;
Hershkovitz, I .
SPINE, 2004, 29 (16) :1755-1763