Estimation of polyvinyl alcohol cryogel mechanical properties with four ultrasound elastography methods and comparison with gold standard testings

被引:176
作者
Fromageau, Jeremie [1 ]
Gennisson, Jean-Luc
Schmitt, Cedric
Maurice, Roch L.
Mongrain, Rosaire
Cloutier, Guy
机构
[1] Univ Montreal Hosp, Lab Biorheol & Med Ultrason, Res Ctr, Montreal, PQ H2L 2W5, Canada
[2] McGill Univ, Dept Mech Engn, Montreal, PQ H3A 2K6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
10.1109/TUFFC.2007.273
中图分类号
O42 [声学];
学科分类号
070206 [声学]; 082403 [水声工程];
摘要
Tissue-mimicking phantoms are very useful in the field of tissue characterization and essential in elastography for the purpose of validating motion estimators. This study is dedicated to the characterization of polyvinyl alcohol cryogel (PVA-C) for these types of applications. A strict fabrication procedure was defined to optimize the reproducibility of phantoms having a similar elasticity. Following mechanical stretching tests, the phantoms were used to compare the accuracy of four different elastography methods. The four methods were based on a one-dimensional (I-D) scaling factor estimation, on two different implementations of a 2-D Lagrangian speckle model estimator (quasistatic elastography methods), and on a I-D shear wave transient elastography technique (dynamic method). Young's modulus was investigated as a function of the number of freeze-thaw cycles of PVA-C, and of the concentration of acoustic scatterers. Other mechanical and acoustic parameters-such as the speed of sound, shear wave velocity, mass density, and Poisson's ratio-also were assessed. The Poisson's ratio was estimated with good precision at 0.499 for all samples, and the Young's moduli varied in a range of 20 kPa for one freeze-thaw cycle to 600 kPa for 10 cycles. Nevertheless, above six freeze-thaw cycles, the results were less reliable because of sample geometry artifacts. However, for the samples that underwent less than seven freeze-thaw cycles, the Young's moduli estimated with the four elastography methods showed good matching with the mechanical tensile tests with a regression coefficient varying from 0.97 to 1.07, and correlations R-2 varying from 0.93 to 0.99, depending on the method.
引用
收藏
页码:498 / 509
页数:12
相关论文
共 39 条
[1]
An adaptive strain estimator for elastography [J].
Alam, SK ;
Ophir, J ;
Konofagou, EE .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (02) :461-472
[2]
Axial strain imaging using a local estimation of the scaling factor from RF ultrasound signals [J].
Brusseau, E ;
Perrey, C ;
Delachartre, P ;
Vogt, M ;
Vray, D ;
Ermert, H .
ULTRASONIC IMAGING, 2000, 22 (02) :95-107
[3]
A solution to diffraction biases in sonoelasticity: The acoustic impulse technique [J].
Catheline, S ;
Wu, F ;
Fink, M .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1999, 105 (05) :2941-2950
[4]
Diffraction field of a low frequency vibrator in soft tissues using transient elastography [J].
Catheline, S ;
Thomas, JL ;
Wu, F ;
Fink, MA .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (04) :1013-1019
[5]
Tissue mimicking materials for a multi-imaging modality prostate phantom [J].
D'Souza, WD ;
Madsen, EL ;
Unal, O ;
Vigen, KK ;
Frank, GR ;
Thomadsen, BR .
MEDICAL PHYSICS, 2001, 28 (04) :688-700
[6]
de Korte C L, 1998, Eur J Ultrasound, V7, P219, DOI 10.1016/S0929-8266(98)00043-3
[7]
MEASUREMENT OF SOFT-TISSUE MOTION USING CORRELATION BETWEEN A-SCANS [J].
DICKINSON, RJ ;
HILL, CR .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1982, 8 (03) :263-271
[8]
Du HN, 2004, ULTRASON, P32
[9]
Elshazly T., 2004, THESIS GEORGIA I TEC
[10]
Characterization of PVA cryogel for intravascular ultrasound elasticity imaging [J].
Fromageau, J ;
Brusseau, E ;
Vray, D ;
Gimenez, G ;
Delachartre, P .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (10) :1318-1324