Optimal gradient operation in comprehensive liquid chromatography x liquid chromatography systems with limited orthogonality

被引:48
作者
Bedani, Filippo [1 ]
Kok, Wim Th. [1 ]
Janssen, Hans-Gerd [1 ,2 ]
机构
[1] Univ Amsterdam, Vant Hoff Inst Mol Sci, Polymer Anal Grp, NL-1018 WV Amsterdam, Netherlands
[2] Unilever Res Labs, Adv Measurement & Imaging, NL-3130 AC Vlaardingen, Netherlands
关键词
Comprehensive two-dimensional liquid chromatography; On-line two-dimensional liquid chromatography; Peak capacity; Analysis time; Orthogonality; Peptide analysis; 2-DIMENSIONAL SEPARATIONS; PEAK-CAPACITY; 1ST-DIMENSION; PEPTIDES; PHASE;
D O I
10.1016/j.aca.2009.06.042
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel strategy is described for designing optimal second dimension (D-2) gradient conditions for a comprehensive two-dimensional liquid chromatography system where the two dimensions are not fully orthogonal. Using the approach developed here, the initial and final organic modifier content values resulting in the highest coverage of separation space can be derived for each D-2 gradient run. Theory indicates that these values can be determined by adapting D-2 gradient operation to the degree of orthogonality. The new method is tested on a comprehensive two-dimensional liquid chromatography system that uses reversed phase (RP) columns showing different selectivities in the two dimensions. A comparison between analyses carried out using normal and optimized D-2 gradients showed that the latter allow a more efficient use of analysis time. This can result either in an improved peak capacity or in decreasing total analysis time, depending on the final goal of the experiment. In the latter scenario, the number of separated peaks is comparable to that obtained using gradients spanning a wide range of organic modifier but, now, in half the time. As test samples complex mixtures of peptides were analyzed. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:77 / 84
页数:8
相关论文
共 20 条
[1]   A theoretical basis for parameter selection and instrument design in comprehensive size-exclusion chromatography x liquid chromatography [J].
Bedani, Filippo ;
Kok, Wim Th. ;
Janssen, Hans-Gerd .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1133 (1-2) :126-134
[2]  
Blomberg J., 1997, J HIGH RES CHROMATOG, V20, P539
[3]   Effect of first-dimension undersampling on effective peak capacity in comprehensive two-dimensional separations [J].
Davis, Joe M. ;
Stoll, Dwight R. ;
Carr, Peter W. .
ANALYTICAL CHEMISTRY, 2008, 80 (02) :461-473
[4]   Evaluation of the two-dimensional reversed-phase-reversed-phase separations of low-molecular mass polystyrenes [J].
Gray, MJ ;
Dennis, GR ;
Slonecker, PJ ;
Shalliker, RA .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1015 (1-2) :89-98
[5]   Implementations of two-dimensional liquid chromatography [J].
Guiochon, Georges ;
Marchetti, Nicola ;
Mriziq, Khaled ;
Shalliker, R. Andrew .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1189 (1-2) :109-168
[6]  
Karger B.L., 1973, INTRO SEPARATION SCI
[7]   Simple 2D-HPLC using a monolithic silica column for peptide separation [J].
Kimura, H ;
Tanigawa, T ;
Morisaka, H ;
Ikegami, T ;
Hosoya, K ;
Ishizuka, N ;
Minakuchi, H ;
Nakanishi, K ;
Ueda, M ;
Cabrera, K ;
Tanaka, N .
JOURNAL OF SEPARATION SCIENCE, 2004, 27 (10-11) :897-904
[8]   Click oligo(ethylene glycol): An excellent orthogonal stationary phase to C18 for two-dimensional reversed-phase/reversed-phase liquid chromatography [J].
Liu, Yanming ;
Guo, Zhimou ;
Jin, Yu ;
Xue, Xingya ;
Xu, Qing ;
Zhang, Feifang ;
Liang, Xinmiao .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1206 (02) :153-159
[9]   Two-dimensional LC-MS analysis of components in Swertia franchetiana Smith [J].
Liu, Yanming ;
Xu, Qing ;
Xue, Xingya ;
Zhang, Feifang ;
Liang, Xinmiao .
JOURNAL OF SEPARATION SCIENCE, 2008, 31 (6-7) :935-944
[10]   GEOMETRIC APPROACH TO FACTOR-ANALYSIS FOR THE ESTIMATION OF ORTHOGONALITY AND PRACTICAL PEAK-CAPACITY IN COMPREHENSIVE 2-DIMENSIONAL SEPARATIONS [J].
LIU, ZY ;
PATTERSON, DG ;
LEE, ML .
ANALYTICAL CHEMISTRY, 1995, 67 (21) :3840-3845