Volumetric quantitative computed tomography of the proximal femur: Precision and relation to bone strength

被引:213
作者
Lang, TF
Keyak, JH
Heitz, MW
Augat, P
Lu, Y
Mathur, A
Genant, HK
机构
[1] DEPT VET AFFAIRS MED CTR,REHABIL RES & DEV SERV,SAN FRANCISCO,CA
[2] UNIV CALIF SAN FRANCISCO,BIOENGN GRAD GRP,SAN FRANCISCO,CA 94143
关键词
quantitative computed tomography; bone mineral density; proximal femur; cross-sectional geometry; biomechanics; bone strength;
D O I
10.1016/S8756-3282(97)00072-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We have developed a three-dimensional computed tomography (CT) scanning and image analysis method for measurement of trabecular and integral bone mineral density (BMD) and geometry in automatically determined femoral-neck and trochanteric subregions of the proximal femur, We measured the correlation of the density and geometry variables to femoral strength assessed in vitro under loading simulating a single-limb condition and a fall to the side. While BMD alone accounted for 48%-77% of the variability in strength for the stance loading configuration, femoral neck cross-sectional area (minCSA) and femoral neck axis length (FNAL) also contributed independently to femoral strength, and a combination of BMD and geometry variables explained 87%-93% of the variance in the data, For the fall loading configuration, trochanteric trabecular BMD alone explained 87% of the variability of strength. The reproducibility in vivo of the technique was assessed in a group of seven postmenopausal women, who underwent repeat scans with repositioning, For trabecular BMD, the precision was 1.1% and 0.6% for the femoral neck and trochanteric subregions, respectively, compared to 3.3% and 1.6% for the corresponding integral envelopes, Thus, trabecular BMD measurements were reproducible and highly correlated to biomechanical strength measurements. These results support further exploration of quantitative CT for assessment of osteoporosis at the proximal femur. (C) 1997 by Elsevier Science Inc. All rights reserved.
引用
收藏
页码:101 / 108
页数:8
相关论文
共 44 条
[1]  
ALHO A, 1988, CLIN ORTHOPAEDICS, V227, P292
[2]  
[Anonymous], FEMORAL NECK FUNCTIO
[3]   PREDICTING FEMORAL-NECK STRENGTH FROM BONE-MINERAL DATA - A STRUCTURAL APPROACH [J].
BECK, TJ ;
RUFF, CB ;
WARDEN, KE ;
SCOTT, WW ;
RAO, GU .
INVESTIGATIVE RADIOLOGY, 1990, 25 (01) :6-18
[4]   3-DIMENSIONAL QUANTITATIVE CT OF THE PROXIMAL FEMUR - RELATIONSHIP TO VERTEBRAL TRABECULAR BONE-DENSITY IN POSTMENOPAUSAL WOMEN [J].
BHASIN, S ;
SARTORIS, DJ ;
FELLINGHAM, L ;
ZLATKIN, MB ;
ANDRE, M ;
RESNICK, D .
RADIOLOGY, 1988, 167 (01) :145-149
[5]  
BLOCK JE, 1989, J BONE MINER RES, V4, P249
[6]   ULTRASOUND AND DENSITOMETRY OF THE CALCANEUS CORRELATE WITH THE FAILURE LOADS OF CADAVERIC FEMURS [J].
BOUXSEIN, ML ;
COURTNEY, AC ;
HAYES, WC .
CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (02) :99-103
[7]  
CANN C, 1996, J BIOMED MATER RES, V11, pS479
[8]   Predictive value of proximal femoral bone densitometry in determining local orthogonal material properties [J].
Cody, DD ;
McCubbrey, DA ;
Divine, GW ;
Gross, GJ ;
Goldstein, SA .
JOURNAL OF BIOMECHANICS, 1996, 29 (06) :753-761
[9]   EFFECTS OF LOADING RATE ON STRENGTH OF THE PROXIMAL FEMUR [J].
COURTNEY, AC ;
WACHTEL, EF ;
MYERS, ER ;
HAYES, WC .
CALCIFIED TISSUE INTERNATIONAL, 1994, 55 (01) :53-58
[10]   AGE-RELATED REDUCTIONS IN THE STRENGTH OF THE FEMUR TESTED IN A FALL-LOADING CONFIGURATION [J].
COURTNEY, AC ;
WACHTEL, EF ;
MYERS, ER ;
HAYES, WC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (03) :387-395