Association between indices of prosthesis internal orifice size and operative mortality after isolated aortic valve replacement

被引:24
作者
Bridges, Charles R.
O'Brien, Sean M.
Cleveland, Joseph C.
Savage, Edward B.
Gammie, James S.
Edwards, Fred H.
Peterson, Eric D.
Grover, Frederick L.
机构
[1] Univ Penn, Hlth Syst, Dept Surg, Philadelphia, PA 19104 USA
[2] Univ Penn, Hlth Syst, Dept Bioengn, Philadelphia, PA 19104 USA
[3] Duke Clin Res Inst, Durham, NC USA
[4] Univ Colorado, Dept Surg, Denver, CO 80202 USA
[5] Rush Univ, Dept Cardiovasc Thorac Surg, Chicago, IL 60612 USA
[6] Univ Maryland, Med Ctr, Dept Surg, Baltimore, MD 21201 USA
[7] Univ Florida, Dept Surg, Jacksonville, FL USA
关键词
D O I
10.1016/j.jtcvs.2006.11.028
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The appropriate index of prosthesis internal orifice size and its effect on operative mortality after aortic valve replacement are controversial. We examined the association between several relevant indices and patient size on operative mortality. Indices examined included projected in vivo effective orifice area and geometric orifice area, with patient size defined as body surface area. Methods: A review of the Society of Thoracic Surgeons National Cardiac Database (2000-2004) yielded 48,722 patients who had isolated aortic valve replacement. This analysis is based on the cohort of 42,310 patients with the 8 most prevalent valve types with manufacturer's labeled sizes 19 mm through 29 mm. Multivariable logistic regression models were employed to determine the effects of body surface area, effective orifice area, geometric orifice area, and selected derived indices (eg, effective orifice area/ body surface area) on risk-adjusted operative mortality. Results: In separate multivariable models, effective orifice area and geometric orifice area were both inversely correlated with operative mortality. However, an unanticipated finding was that with either effective orifice area or geometric orifice area held constant, body surface area was significantly and inversely correlated with operative mortality. When patients were stratified by effective orifice area, geometric orifice area, or manufacturer's labeled valve size and type, elevations in body surface area were associated with a decrease rather than an increase in operative mortality. Conclusions: Prostheses with small geometric orifice area or small effective orifice area are associated with increased operative mortality after isolated aortic valve replacement. Even for valves with small effective orifice area, however, mortality decreases as body surface area increases. With respect to operative mortality, therefore, our results do not support using arbitrary cutoff values of effective orifice area/ body surface area to determine the valve to utilize in a given patient.
引用
收藏
页码:1012 / +
页数:12
相关论文
共 37 条
[1]  
Autschbach R, 2000, CIRCULATION, V102, P1
[2]   Normal echocardiographic characteristics of the Sorin Bicarbon bileaflet prosthetic heart valve in the mitral and aortic positions [J].
Badano, L ;
Mocchegiani, R ;
Bertoli, D ;
DeGaetano, G ;
Carratino, L ;
Pasetti, L ;
Caudullo, M ;
Budini, A ;
Mannello, B ;
Passerone, G .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1997, 10 (06) :632-643
[3]  
Barratt-Boyes B G, 1987, J Card Surg, V2, P435, DOI 10.1111/j.1540-8191.1987.tb00203.x
[4]   Prosthesis size and long-term survival after aortic valve replacement [J].
Blackstone, EH ;
Cosgrove, DM ;
Jamieson, WRE ;
Birkmeyer, NJ ;
Lemmer, JH ;
Miller, DC ;
Butchart, EG ;
Rizzoli, G ;
Yacoub, M ;
Chai, AK .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (03) :783-796
[5]   Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement [J].
Blais, C ;
Dumesnil, JG ;
Baillot, R ;
Simard, S ;
Doyle, D ;
Pibarot, P .
CIRCULATION, 2003, 108 (08) :983-988
[6]   Body surface area as a predictor of aortic and pulmonary valve diameter [J].
Capps, SB ;
Elkins, RC ;
Fronk, DM .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2000, 119 (05) :975-982
[7]   DOPPLER ECHOCARDIOGRAPHIC ASSESSMENT OF THE ST-JUDE MEDICAL PROSTHETIC VALVE IN THE AORTIC POSITION USING THE CONTINUITY EQUATION [J].
CHAFIZADEH, ER ;
ZOGHBI, WA .
CIRCULATION, 1991, 83 (01) :213-223
[8]   ECHOCARDIOGRAPHIC DESCRIPTION OF THE CARBOMEDICS BILEAFLET PROSTHETIC HEART-VALVE [J].
CHAMBERS, J ;
CROSS, J ;
DEVERALL, P ;
SOWTON, E .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (02) :398-405
[9]   Nominal size in six bileaflet mechanical aortic valves: A comparison of orifice size and biologic equivalence [J].
Chambers, JB ;
Oo, L ;
Narracott, A ;
Lawford, PM ;
Blauth, CI .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 125 (06) :1388-1393
[10]   Inaccurate and misleading valve sizing: A proposed standard for valve size nomenclature [J].
Christakis, GT ;
Buth, KJ ;
Goldman, BS ;
Fremes, SE ;
Rao, V ;
Cohen, G ;
Borger, MA ;
Weisel, RD .
ANNALS OF THORACIC SURGERY, 1998, 66 (04) :1198-1203