Comparison of the Cepheid GeneXpert and Abbott M2000 HIV-1 real time molecular assays for monitoring HIV-1 viral load and detecting HIV-1 infection

被引:57
作者
Ceffa, Susanna [1 ]
Luhanga, Richard [2 ]
Andreotti, Mauro [3 ]
Brambilla, Davide [1 ]
Erba, Fulvio [4 ]
Jere, Haswel [2 ]
Mancinelli, Sandro [5 ]
Giuliano, Marina [3 ]
Palombi, Leonardo [5 ]
Marazzi, Maria Cristina [6 ]
机构
[1] Community S Egidio, DREAM Program, Via di San Gallicano 25, I-00153 Rome, Italy
[2] DREAM Hlth Ctr, Community S Egidio, DREAM Program, Jacaranda Ave,POB 30355 Mandala Chichiri Blantyre, Zomba, Malawi
[3] Ist Super Sanita, Dept Therapeut Res & Med Evaluat, Viale Regina Elena 299, I-00161 Rome, Italy
[4] Univ Roma Tor Vergata, Dept Clin Sci & Translat Med, Via Tor Vergata, Rome, Italy
[5] Univ Roma Tor Vergata, Dept Biomed & Prevent, Via Montpellier 1, I-00133 Rome, Italy
[6] LUMSA Univ, Dept Community Hlth, Via Transpontina 21, I-00193 Rome, Italy
关键词
HIV-1; POC tests; Viral load; Early infant diagnosis; DIAGNOSIS;
D O I
10.1016/j.jviromet.2015.12.007
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
Assessing treatment efficacy and early infant diagnosis (EID) are critical issues in HIV disease management. Point-of-care assays may greatly increase the possibility to access laboratory monitoring also in rural areas. Recently two new laboratory tests have been developed by Cepheid (Sunnyvale, California) the Xpert HIV-1 Viral Load for viral load determination and the Xpert HIV-1 Qualitative for early infant diagnosis. We conducted a study in Blantyre, Malawi, comparing the 2 methods versus the Abbott real time quantitative and qualitative assays, for viral load and EID respectively. We tested 300 plasma samples for viral load determination and 200 samples for infant diagnosis. HIV-1 RNA values of the 274 samples quantified by both assays were highly correlated (Pearson r=0.95, R-2=0.90). In 90.9% of the cases the two methods were concordant in defining the HIV-1 RNA levels as detectable or undetectable. For EID, the Xpert HIV-1 Qualitative assay yielded the same identical results as the Abbott assay. Both the quantitative and the qualitative Xpert assays are promising tools to monitor treatment efficacy in HIV patients receiving treatment and for early diagnosis in HIV-exposed infants. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:35 / 39
页数:5
相关论文
共 16 条
[1]
HIV point-of-care diagnostics: meeting the special needs of sub-Saharan Africa [J].
Aleku, Godwin A. ;
Adoga, Moses P. ;
Agwale, Simon M. .
JOURNAL OF INFECTION IN DEVELOPING COUNTRIES, 2014, 8 (10) :1231-1243
[2]
[Anonymous], GLOB UPD HIV TREATM
[3]
[Anonymous], OPEN AIDS J
[4]
[Anonymous], 2014, HIV AIDS DIAGN TECHN
[5]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]
Feasibility, diagnostic accuracy, and effectiveness of decentralised use of the Xpert MTB/RIF test for diagnosis of tuberculosis and multidrug resistance: a multicentre implementation study [J].
Boehme, Catharina C. ;
Nicol, Mark P. ;
Nabeta, Pamela ;
Michael, Joy S. ;
Gotuzzo, Eduardo ;
Tahirli, Rasim ;
Gler, Ma Tarcela ;
Blakemore, Robert ;
Worodria, William ;
Gray, Christen ;
Huang, Laurence ;
Caceres, Tatiana ;
Mehdiyev, Rafail ;
Raymond, Lawrence ;
Whitelaw, Andrew ;
Sagadevan, Kalaiselvan ;
Alexander, Heather ;
Albert, Heidi ;
Cobelens, Frank ;
Cox, Helen ;
Alland, David ;
Perkins, Mark D. .
LANCET, 2011, 377 (9776) :1495-1505
[7]
Evidence-Based Point-of-Care Diagnostics: Current Status and Emerging Technologies [J].
Chan, Cangel Pui Yee ;
Mak, Wing Cheung ;
Cheung, Kwan Yee ;
Sin, King Keung ;
Yu, Cheuk Man ;
Rainer, Timothy H. ;
Renneberg, Reinhard .
ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 6, 2013, 6 :191-211
[8]
Accurate Early Infant HIV Diagnosis in Primary Health Clinics Using a Point-of-Care Nucleic Acid Test [J].
Jani, Ilesh V. ;
Meggi, Bindiya ;
Mabunda, Nedio ;
Vubil, Adolfo ;
Sitoe, Nadia E. ;
Tobaiwa, Ocean ;
Quevedo, Jorge I. ;
Lehe, Jonathan D. ;
Loquiha, Osvaldo ;
Vojnov, Lara ;
Peter, Trevor F. .
JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2014, 67 (01) :E1-E4
[9]
Evaluating adherence to highly active antiretroviral therapy with use of pill counts and viral load measurement in the drug resources enhancement against AIDS and malnutrition program in Mozambique [J].
Lio, Massimo Magnano San ;
Carbini, Riccardo ;
Germano, Paola ;
Guidotti, Giovanni ;
Mancinelli, Sandro ;
Magid, Noorjehan Abdul ;
Narciso, Pasquale ;
Palombi, Leonardo ;
Renzi, Elsa ;
Zimba, Ines ;
Marazzi, Maria Cristina .
CLINICAL INFECTIOUS DISEASES, 2008, 46 (10) :1609-1616
[10]
Evaluation of the RealTime HIV-1, Xpert HIV-1, and Aptima HIV-1 Quant Dx Assays in Comparison to the NucliSens EasyQ HIV-1 v2.0 Assay for Quantification of HIV-1 Viral Load [J].
Mor, Orna ;
Gozlan, Yael ;
Wax, Marina ;
Mileguir, Fernando ;
Rakovsky, Avia ;
Noy, Bina ;
Mendelson, Ella ;
Levy, Itzchak .
JOURNAL OF CLINICAL MICROBIOLOGY, 2015, 53 (11) :3458-3465