Mass Cytometry: Technique for Real Time Single Cell Multitarget Immunoassay Based on Inductively Coupled Plasma Time-of-Flight Mass Spectrometry

被引:1029
作者
Bandura, Dmitry R. [1 ]
Baranov, Vladimir I. [1 ]
Ornatsky, Olga I. [1 ]
Antonov, Alexei [2 ]
Kinach, Robert [1 ]
Lou, Xudong [1 ]
Pavlov, Serguei [2 ]
Vorobiev, Sergey [2 ]
Dick, John E. [3 ]
Tanner, Scott D. [1 ,2 ]
机构
[1] Univ Toronto, Dept Chem, Toronto, ON M5S 3H6, Canada
[2] DVS Sci Inc, Richmond Hill, ON L4S 1Z5, Canada
[3] Univ Hlth Network, Toronto, ON M5G 1L7, Canada
关键词
ELEMENT-TAGGED IMMUNOASSAY; FLOW-CYTOMETRY; ICP-MS; ANTIGEN;
D O I
10.1021/ac901049w
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
A novel instrument for real time analysis of individual biological cells or other microparticles is described. The instrument is based on inductively coupled plasma time-of-flight mass spectrometry and comprises a three-aperture plasma-vacuum interface, a dc quadrupole turning optics for decoupling ions from neutral components, an rf quadrupole ion guide discriminating against low-mass dominant plasma ions, a point-to-parallel focusing de quadrupole doublet, an orthogonal acceleration reflectron analyzer, a discrete dynode fast ion detector, and an 8-bit 1 GHz digitizer. A high spectrum generation frequency of 76.8 kHz provides capability for collecting multiple spectra from each particle-induced transient ion cloud, typically of 200-300 mu s duration. It is shown that the transients can be resolved and characterized individually at a peak frequency of 1100 particles per second. Design considerations and optimization data are presented. The figures of merit of the instrument are measured under standard inductively coupled plasma (ICP) operating conditions (<3% cerium oxide ratio). At mass resolution (full width at half-maximum) M/Delta M > 900 for m/z = 159, the sensitivity with a standard sample introduction system of > 1.4 x 10(8) ion counts per second per mg L-1 of Tb and an abundance sensitivity of (6 x 10(-4))-(1.4 x 10(-3)) (trailing and leading masses, respectively) are shown. The mass range (m/z = 125-215) and abundance sensitivity are sufficient for elemental immunoassay with up to 60 distinct available elemental tags. When <15 elemental tags are used, a higher sensitivity mode at lower resolution (M/Delta M > 500) can be used, which provides > 2.4 x 10(8) cps per mg L-1 of Tb, at (1.5 x 10(-3))-(5.0 x 10(-3)) abundance sensitivity. The real-time simultaneous detection of multiple isotopes from individual 1.8 mu m polystyrene heads labeled with lanthanides is shown. A real time single cell 20 antigen expression assay of model cell lines and leukemia patient samples immuno-labeled with lanthanide-tagged antibodies is presented.
引用
收藏
页码:6813 / 6822
页数:10
相关论文
共 41 条
[1]
TIME-OF-FLIGHT MASS REFLECTRON WITH A LARGE-AREA OF ION COLLECTION [J].
BANDURA, DR ;
MAKAROV, AA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1993, 127 :45-55
[2]
BARANOV V, 2006, Patent No. 7135296
[3]
A sensitive and quantitative element-tagged immunoassay with ICPMS detection [J].
Baranov, VI ;
Quinn, Z ;
Bandura, DR ;
Tanner, SD .
ANALYTICAL CHEMISTRY, 2002, 74 (07) :1629-1636
[4]
Baranov VI., 2001, European Winter Conference on Plasma Spectrochemistry, P85
[5]
Semiconductor nanocrystals as fluorescent biological labels [J].
Bruchez, M ;
Moronne, M ;
Gin, P ;
Weiss, S ;
Alivisatos, AP .
SCIENCE, 1998, 281 (5385) :2013-2016
[6]
Determination of peanut allergens in cereal-chocolate-based snacks: metal-tag inductively coupled plasma mass spectrometry immunoassay versus liquid chromatography/electrospray ionization tandem mass spectrometry [J].
Careri, Maria ;
Elviri, Lisa ;
Maffini, Monica ;
Mangia, Alessandro ;
Mucchino, Claudio ;
Terenghi, Mattia .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (06) :807-811
[7]
Orthogonal-injection TOFMS for analyzing biomolecules [J].
Chernushevich, IV ;
Ens, W ;
Standing, KG .
ANALYTICAL CHEMISTRY, 1999, 71 (13) :452A-461A
[8]
Ionizing radiation effects on the KG1a primitive hematopoietic cell line [J].
Clave, E ;
Carosella, ED ;
Gluckman, E ;
Dubray, B ;
Socie, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (04) :709-719
[9]
Guilhaus M, 2000, MASS SPECTROM REV, V19, P65, DOI 10.1002/(SICI)1098-2787(2000)19:2<65::AID-MAS1>3.0.CO
[10]
2-E