Suture-Button Versus Screw Fixation of the Syndesmosis: A Biomechanical Analysis

被引:137
作者
Klitzman, Robert [1 ]
Zhao, Heng [1 ]
Zhang, Li-Qun [1 ]
Strohmeyer, Greg [1 ]
Vora, Anand [1 ]
机构
[1] NW Dept Orthopaed Surg, Chicago, IL 60611 USA
关键词
Syndesmosis; Ankle; Tightrope; Biomechanical; Cadaveric; PER; ANKLE FRACTURES; TIBIOFIBULAR SYNDESMOSIS; INJURIES; CADAVER; DISRUPTIONS; DIASTASIS; MOTION; JOINT; AREA;
D O I
10.3113/FAI.2010.0069
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: The treatment of ankle fractures with syndesmotic injuries associated with disruption of the deltoid ligament complex is controversial. The purpose of this study was to compare both the biomechanical and physiologic properties of suture-button fixation to the intact syndesmosis and screw fixation. Materials and Methods: Eight fresh frozen human cadaveric ankles were used in three different groups. One group had an intact syndesmosis and deltoid ligamentous complex and two groups had fixation of the syndesmosis after its disruption along with disruption of the deltoid ligaments. One fixation group used a suture-button and the other used a 3.5-mm tricortical syndesmotic screw. The syndesmotic gap after cycling at submaximal. loads, laxity due to cycling, and fibular movement allowed in the sagittal plane were all measured and analyzed for statistical significance. Results: The syndesmotic gap after cycling was not significantly different between the intact group (9.1 mm) and the suture-button group (8.8 mm) (p = 0.1509). The screw fixation group had a significantly smaller gap (7.9 mm) as compared to the other two groups (screw versus intact, p = 0.00004; screw versus suture-button, p = 0.0004). The intact group did not demonstrate a significant difference in laxity before (9.0 mm) and after (9.1 mm) cycling (p = 0.0670), whereas the suture-button group (lid have a significant difference (before, 8.01 mm; after, 8.28 mm) (p = 0.000251). The movement of the fibula in the sagittal plane was significantly greater in the suture-button group (3.17 mm) as compared to the intact group (2.77 mm) (p = 0.00554). Screw fixation allowed significantly less fibular movement in the sagittal plane (1.16 mm) as compared to the intact (p = 0.00014) and suture-button (p = 0.0000012) groups. Conclusion: Suture-button fixation maintained reduction after cycling with submaximal loads that compared favorably to the intact syndesmosis. It also allowed more physiologic movement of the fibula in the sagittal plane when compared to tricortical screw fixation. Clinical Relevance: Syndesmotic injury fixation has traditionally used screws to provide a rigid construct in which healing can take place. We believe a less rigid fixation method, such as suture-button fixation, provides a more physiologic type of healing of the syndesmosis.
引用
收藏
页码:69 / 75
页数:7
相关论文
共 31 条
[1]
Syndesmotic screw fixation in Weber C ankle injuries-should the screw be removed before weight bearing? [J].
Bell, David Paul ;
Wong, Merng Koon .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2006, 37 (09) :891-898
[2]
MECHANICAL CONSIDERATIONS FOR THE SYNDESMOSIS SCREW - A CADAVER STUDY [J].
BODEN, SD ;
LABROPOULOS, PA ;
MCCOWIN, P ;
LESTINI, WF ;
HURWITZ, SR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (10) :1548-1555
[3]
TIBIOTALAR JOINT DYNAMICS - INDICATIONS FOR THE SYNDESMOTIC SCREW - A CADAVER STUDY [J].
BURNS, WC ;
PRAKASH, K ;
ADELAAR, R ;
BEAUDOIN, A ;
KRAUSE, W .
FOOT & ANKLE, 1993, 14 (03) :153-158
[4]
CHISSELL HR, 1995, J BONE JOINT SURG BR, V77B, P435
[5]
Injuries to the tibiofibular syndesmosis [J].
Dattani, R. ;
Patnaik, S. ;
Kantak, A. ;
Srikanth, B. ;
Selvan, T. P. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (04) :405-410
[6]
Ankle fractures and syndesmosis injuries [J].
Donatto, KC .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2001, 32 (01) :79-+
[7]
Comparison of a novel FiberWire-button construct versus metallic screw fixation in a syndesmotic injury model [J].
Forsythe, Kevin ;
Freedman, Kevin B. ;
Stover, Michael D. ;
Patwardhan, Avinash G. .
FOOT & ANKLE INTERNATIONAL, 2008, 29 (01) :49-54
[8]
HEALING OF THE MEDIAL COLLATERAL LIGAMENT IN RATS - THE EFFECTS OF REPAIR, MOTION, AND SECONDARY STABILIZING LIGAMENTS [J].
HART, DP ;
DAHNERS, LE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1987, 69A (08) :1194-1199
[9]
Tricortical versus quadricortical syndesmosis fixation in ankle fractures - A prospective, randomized study comparing two methods of syndesmosis fixation [J].
Hoiness, P ;
Stromsoe, K .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (06) :331-337
[10]
Treatment of syndesmotic disruptions of the ankle with bioabsorbable screw fixation [J].
Hovis, WD ;
Kaiser, BW ;
Watson, JT ;
Bucholz, RW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (01) :26-31