Establishment of enzyme immunoassay for measuring β-methyldigoxin levels in human serum by specific antiserum

被引:3
作者
Higashi, Y [1 ]
Watanabe, N [1 ]
Sasaki, T [1 ]
Fujii, Y [1 ]
机构
[1] Hokuriku Univ, Fac Pharmaceut Sci, Dept Analyt Chem, Kanazawa, Ishikawa 9201181, Japan
关键词
beta-methyldigoxin; anti-beta-methyldigoxin 3 '-hemisuccinate-BSA antiserum; phenyl boric acid column; anti-digoxin antiserum; enzyme immunoassay; cross-reactivity;
D O I
10.1248/bpb.25.1251
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
\We investigated the specificity of obtained antisera to beta-methyldigoxin by the enzyme immunoassay. Three types of hapten-bovine serum albumin (BSA) conjugates were synthesized to obtain high specific antisera to methyldigoxin. The haptens were linked to the carrier protein through hemisuccinate at C-3' and C-3" positions in the digitoxose chain and at C-12 position in the aglycone. Anti-beta-methyldigoxin 3'-hemisuccinate-BSA antiserum showed a low'detection limit (0.2 ng/ml) and possessed high specificity for beta-methyldigoxin, exhibiting low cross-reactions with digoxigenin bisdigitoxoside (8.3%), dihydrodigoxin (4.8%), digitoxin (1.5%), and digoxigenin monodigitoxoside (0.95%), except for cross-reaction with digoxin (43%). Compared with commercial anti-digoxin antiserum, clinically used to monitor beta-methyldigoxin concentration in human serum, cross-reaction data of anti-beta-methyldigoxin 3'-hemisuccinate-BSA antiserum showed higher specificity for beta-methyldigoxin. The intra-assay and inter-assay variations using this antiserum were less than 6.9% and 8.1%, respectively. The recovery tests were good, within the range of 96.2-104.3%. Phenyl boric acid (PBA) column treatment was effective to rapidly and selectively separate beta-methyldigoxin from the mixture of beta-methyldigoxin and its metabolites in human serum. The recovery tests of beta-methyldigoxin with PBA column in human serum were about 110% and interference of metabolites of beta-methyldigoxin was negligible. These results suggest that anti-beta-methyldigoxin 3'-hemisuccinate-BSA antiserum and PBA column treatment are useful to more precisely monitor the unchanged type of beta-methyldigoxin concentration in human serum.
引用
收藏
页码:1251 / 1257
页数:7
相关论文
共 14 条
  • [1] ALAN HBW, 1985, CLIN CHEM, V31, P298
  • [2] DIMSON PA, 1984, CURRENT, V3, P4
  • [3] FUJII Y, 1994, CLIN CHEM, V40, P172
  • [4] FUJII Y, 1994, BIOL PHARM BULL, V17, P467
  • [5] DIGOXIN BIOTRANSFORMATION
    GAULT, MH
    LONGERICH, LL
    LOO, JCK
    KO, PTH
    FINE, A
    VASDEV, SC
    DAWE, MA
    [J]. CLINICAL PHARMACOLOGY & THERAPEUTICS, 1984, 35 (01) : 74 - 82
  • [6] HAACK E, 1957, NATURWISSENSCHAFTEN, V44, P633
  • [7] PHARMACOKINETICS OF BETA-METHYLDIGOXIN IN HEALTHY HUMANS .2. ORAL STUDIES AND BIOAVAILABILITY
    HINDERLING, PH
    GARRETT, ER
    WESTER, RC
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 1977, 66 (03) : 314 - 325
  • [8] PHARMACOKINETICS OF BETA-METHYLDIGOXIN IN HEALTHY HUMANS .1. INTRAVENOUS STUDIES
    HINDERLING, PH
    GARRETT, ER
    WESTER, RC
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 1977, 66 (02) : 242 - 253
  • [9] Ikeda Y, 2000, BIOL PHARM BULL, V23, P906