Disinfection of bronchoscopes, contaminated in vitro with Mycobacterium tuberculosis, Mycobacterium avium-intracellulare and Mycobacterium chelonae in sputum, using stabilized, buffered peracetic acid solution ('Nu-Cidex')

被引:23
作者
Middleton, AM
Chadwick, MV
Gaya, H
机构
[1] Department of Microbiology, Royal Brompton Hospital
关键词
Nu-Cidex; peracetic acid; M-tuberculosis; M-avium-intracellulare; M-chelonae; bronchoscope; disinfection;
D O I
10.1016/S0195-6701(97)90183-3
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The efficacy of 0.35% stabilized buffered peracetic acid solution ('Nu-Cidex') against clinical isolates of Mycobacterium tuberculosis, Mycobacterium avium-intracellulare and Mycobacterium chelonae in homogenized sputum was tested. An in-use method, using an automated bronchoscope washing machine, showed that over 10 cycles, at a disinfectant contact time of 5 min, M. tuberculosis and M. chelonae were effectively eradicated from the bronchoscope, even in the absence of detergent and pre-cleaning. M. avium-intracellulare was not eradicated in only one of 10 cycles with contact times of 5 and 10 min, but numbers were reduced by >7 log(10) and >5 log(10), respectively. With detergent present, M. avium-intracellulare was successfully eradicated in all cycles at a contact time of 5 min or greater. The results demonstrate that peracetic acid is an effective mycobactericidal agent for use in the disinfection of bronchoscopes.
引用
收藏
页码:137 / 143
页数:7
相关论文
共 10 条
[1]  
AYLIFFE GAJ, 1992, J HOSP INFECT, V22, P137
[2]   DISINFECTANT TESTING OF CONTAMINATED ENDOSCOPES - A NEED FOR STANDARDIZATION [J].
CUTLER, RR ;
WILSON, P .
JOURNAL OF HOSPITAL INFECTION, 1993, 25 (02) :145-147
[3]   EVALUATION OF A RADIOMETRIC METHOD FOR STUDYING BACTERIAL-ACTIVITY IN THE PRESENCE OF ANTIMICROBIAL AGENTS [J].
CUTLER, RR ;
WILSON, P ;
CLARKE, FV .
JOURNAL OF APPLIED BACTERIOLOGY, 1989, 66 (06) :515-521
[4]  
HANSON PJV, 1988, THORAX, V46, P850
[5]   In-use stability of Nu-Cidex [J].
Holton, J ;
Shetty, N .
JOURNAL OF HOSPITAL INFECTION, 1997, 35 (03) :245-248
[6]   EFFICACY OF NU-CIDEX (0.35-PERCENT PERACETIC-ACID) AGAINST MYCOBACTERIA AND CRYPTOSPORIDIA [J].
HOLTON, J ;
SHETTY, N ;
MCDONALD, V .
JOURNAL OF HOSPITAL INFECTION, 1995, 31 (03) :235-237
[7]  
JACHUCK SJ, 1989, J SOC OCCUP MED, V38, P69
[8]   COMPARISON OF THE MYCOBACTERICIDAL ACTIVITY OF 2-PERCENT ALKALINE GLUTARALDEHYDE AND NU-CIDEX (0-35-PERCENT PERACETIC-ACID) [J].
LYNAM, PA ;
BABB, JR ;
FRAISE, AP .
JOURNAL OF HOSPITAL INFECTION, 1995, 30 (03) :237-240
[9]   THE EFFICACY OF THE DISINFECTION OF BRONCHOSCOPES CONTAMINATED IN-VITRO WITH MYCOBACTERIUM-TUBERCULOSIS AND MYCOBACTERIUM-AVIUM-INTRACELLULARE IN SPUTUM - A COMPARISON OF SACTIMED-I-SINALD AND GLUTARALDEHYDE [J].
NICHOLSON, G ;
HUDSON, RA ;
CHADWICK, MV ;
GAYA, H .
JOURNAL OF HOSPITAL INFECTION, 1995, 29 (04) :257-264
[10]   GLUTARALDEHYDE RESISTANT MYCOBACTERIA FROM ENDOSCOPE WASHERS [J].
VANKLINGEREN, B ;
PULLEN, W .
JOURNAL OF HOSPITAL INFECTION, 1993, 25 (02) :147-149