Adaptive calibration for object localization in turbid media with interfering diffuse photon density waves

被引:10
作者
Chen, Y [1 ]
Mu, CP
Intes, X
Chance, B
机构
[1] Univ Penn, Dept Biochem & Biophys, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Bioengn, Philadelphia, PA 19104 USA
关键词
D O I
10.1364/AO.41.007325
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The amplitude cancellation method that uses dual out-of-phase sources (a phased array system) can sensitively detect and locate small objects in turbid media. The balance of these two sources is crucial to the system's detection sensitivity and accuracy. We describe a convenient method with which to adaptively calibrate the amplitudes of the two sources at each scanning position by use of low-frequency modulation of the intensity of the in-phase and the antiphase sources. We achieve accurate localization ability of the phased array system by accounting for the influence of asymmetrical boundaries and the heterogeneous background absorption. Experimental data on human breast phantoms demonstrate that localization accuracy within several millimeters has been accomplished through this method. (C) 2002 Optical Society of America.
引用
收藏
页码:7325 / 7333
页数:9
相关论文
共 37 条
[1]   Novel receptor-targeted fluorescent contrast agents for in vivo tumor imaging [J].
Achilefu, S ;
Dorshow, RB ;
Bugaj, JE ;
Rajagopalan, R .
INVESTIGATIVE RADIOLOGY, 2000, 35 (08) :479-485
[2]   Optical tomography in medical imaging [J].
Arridge, SR .
INVERSE PROBLEMS, 1999, 15 (02) :R41-R93
[3]  
Casavola C, 1999, CLIN HEMORHEOL MICRO, V21, P389
[4]   Sources of absorption and scattering contrast for near-infrared optical mammography [J].
Cerussi, AE ;
Berger, AJ ;
Bevilacqua, F ;
Shah, N ;
Jakubowski, D ;
Butler, J ;
Holcombe, RF ;
Tromberg, BJ .
ACADEMIC RADIOLOGY, 2001, 8 (03) :211-218
[5]   Precision localization of hidden absorbers in body tissues with phased-array optical systems [J].
Chance, B ;
Kang, KA ;
He, LB ;
Liu, HL ;
Zhou, SM .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (12) :4324-4332
[6]   HIGHLY SENSITIVE OBJECT LOCATION IN TISSUE MODELS WITH LINEAR IN-PHASE AND ANTIPHASE MULTIELEMENT OPTICAL ARRAYS IN ONE AND 2 DIMENSIONS [J].
CHANCE, B ;
KANG, K ;
HE, L ;
WENG, J ;
SEVICK, E .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1993, 90 (08) :3423-3427
[7]   A novel method for fast imaging of brain function, non-invasively, with light [J].
Chance, B ;
Anday, E ;
Nioka, S ;
Zhou, S ;
Hong, L ;
Worden, K ;
Li, C ;
Murray, T ;
Ovetsky, Y ;
Pidikiti, D ;
Thomas, R .
OPTICS EXPRESS, 1998, 2 (10) :411-423
[8]   Phase measurement of light absorption and scatter in human tissue [J].
Chance, B ;
Cope, M ;
Gratton, E ;
Ramanujam, N ;
Tromberg, B .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (10) :3457-3481
[9]   Signal-to-noise analysis for detection sensitivity of small absorbing heterogeneity in turbid media with single-source and dual-interfering-source [J].
Chen, Y ;
Mu, CP ;
Intes, X ;
Chance, B .
OPTICS EXPRESS, 2001, 9 (04) :212-224
[10]   Preliminary evaluation of dual wavelength phased array imaging on neonatal brain function [J].
Chen, Y ;
Zhou, SM ;
Xie, CH ;
Nioka, S ;
Delivoria-Papadopoulos, M ;
Anday, E ;
Chance, B .
JOURNAL OF BIOMEDICAL OPTICS, 2000, 5 (02) :194-200