Lung CT densitometry in systemic sclerosis - Correlation with lung fuction, exercise testing, and quality of life

被引:98
作者
Camiciottoli, Gianna
Orlandi, Ilaria
Bartolucci, Maurizio
Meoni, Eleonora
Nacci, Francesca
Diciotti, Stefano
Barcaroli, Chiara
Conforti, Maria Letizia
Pistolesi, Massimo
Matucci-Cerinic, Marco
Mascalchi, Mario
机构
[1] Univ Florence, Dept Crit Care, Resp Med Unit, Florence, Italy
[2] Univ Florence, Dept Clin Physiopathol, Radiodiagnost Sect, Florence, Italy
[3] Univ Florence, Dept Internal Med, Rheumatol Unit, Florence, Italy
[4] Univ Florence, Dept Elect & Telecommun, Florence, Italy
关键词
CT; densitometry; histogram analysis; pulmonary function tests; systemic sclerosis;
D O I
10.1378/chest.06-1401
中图分类号
R4 [临床医学];
学科分类号
1002 [临床医学]; 100602 [中西医结合临床];
摘要
Background: To ascertain if analysis of lung density histograms in thin-section CT was more reproducible than visual assessment of lung changes in systemic sclerosis (SSc), and if such density histogram parameters as mean lung attenuation (MLA), skewness, and kurtosis could more closely reflect pulmonary function as well as exercise and quality of life impairment. Methods: The intraoperator and interoperator reproducibility of visual and densitometilic lung CT analysis in 48 SSc patients examined with CT were evaluated by means of weighted kappa Statistics. Univariate and multivariate regression analyses were applied to evaluate the relationship of visual and densitometric CT measurements with functional parameters including functional residual capacity (FRC), FVC, FEV1, diffusion capacity of the lung for carbon monoxide (DLCO), 6-min walking testing (6MWT), and health-related quality of life questionnaire (QLQ) parameters. Results: The intraoperator and interoperator reproducibility of MLA (intraobserver weighted kappa = 0.97; interobserver weighted kappa = 0.96), skewness (intraobserver weighted kappa = 0.89; interobserver weighted kappa = 0.88), and kurtosis (intraobserver weighted kappa = 0.89; interobserver weighted kappa = 0.88) were higher than those of visual assessment (intraobserver weighted kappa = 0.71; interobserver weighted kappa = 0.69). In univariate analysis, only densitometric measurements were correlated with some exercise and QLQ parameters. In multivariate analysis, MLA (square regression coefficient corrected [R(2)c] = 0.70), skewness (R(2)c = 0.78), and kurtosis (R(2)c = 0.77) were predicted by FRC, FVC, DLCO, 6MWT, and QLQ parameters, while visual assessment was associated only with FRC and FVC (R(2)c = 0.40). Conclusions: In SSc, densitometric analysis is more reproducible than visual assessment of lung changes in thin-section CT and more closely correlated to pulmonary function testing, 6MWT, and QLQ. Density histogram parameters may be useful for cross-sectional and longitudinal studies of lung involvement in SSc.
引用
收藏
页码:672 / 681
页数:10
相关论文
共 37 条
[2]
[Anonymous], 1995, AM J RESP CRIT CARE, V152, P2185
[3]
[Anonymous], 1999, PRACTICAL STAT MED R
[4]
Diagnosis and differential assessment of pulmonary arterial hypertension [J].
Barst, RJ ;
McGoon, M ;
Torbicki, A ;
Sitbon, O ;
Krowka, MJ ;
Olschewski, H ;
Gaine, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (12) :40S-47S
[5]
Quantitative CT indexes in idiopathic pulmonary fibrosis: Relationship with physiologic impairment [J].
Best, AC ;
Lynch, AM ;
Bozic, CM ;
Miller, D ;
Grunwald, GK ;
Lynch, DA .
RADIOLOGY, 2003, 228 (02) :407-414
[6]
Density gradient of the lung parenchyma at computed tomographic scanning in patients with pulmonary hypertension and systemic sclerosis [J].
Cailes, JB ;
duBois, RM ;
Hansell, DM .
ACADEMIC RADIOLOGY, 1996, 3 (09) :724-730
[7]
Cryptogenic fibrosing alveolitis and the fibrosing alveolitis of systemic sclerosis: Morphological differences on computed tomographic scans [J].
Chan, TYK ;
Hansell, DM ;
Rubens, MB ;
duBois, RM ;
Wells, AU .
THORAX, 1997, 52 (03) :265-270
[8]
OBSERVER VARIATION IN PATTERN TYPE AND EXTENT OF DISEASE IN FIBROSING ALVEOLITIS ON THIN-SECTION COMPUTED-TOMOGRAPHY AND CHEST RADIOGRAPHY [J].
COLLINS, CD ;
WELLS, AU ;
HANSELL, DM ;
MORGAN, RA ;
MACSWEENEY, JE ;
DUBOIS, RM ;
RUBENS, MB .
CLINICAL RADIOLOGY, 1994, 49 (04) :236-240
[9]
ATS statement: Guidelines for the six-minute walk test [J].
Crapo, RO ;
Casaburi, R ;
Coates, AL ;
Enright, PL ;
MacIntyre, NR ;
McKay, RT ;
Johnson, D ;
Wanger, JS ;
Zeballos, RJ ;
Bittner, V ;
Mottram, C .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 166 (01) :111-117
[10]
PATHOLOGIC OBSERVATIONS IN SYSTEMIC SCLEROSIS (SCLERODERMA) - A STUDY OF 58 AUTOPSY CASES AND 58 MATCHED CONTROLS [J].
DANGELO, WA ;
FRIES, JF ;
MASI, AT ;
SHULMAN, LE .
AMERICAN JOURNAL OF MEDICINE, 1969, 46 (03) :428-+