Multi-detection of corticosteroids in sports doping and veterinary control using high-resolution liquid chromatography/time-of-flight mass spectrometry

被引:80
作者
Touber, M. E.
van Engelen, M. C.
Georgakopoulus, C.
van Rhijn, J. A.
Nielen, M. W. F.
机构
[1] RIKILT Inst Food Safety, NL-6700 AE Wageningen, Netherlands
[2] Olymp Athlet Ctr Athens, Doping Control Lab Athens, Athens 15123, Greece
关键词
steroids; liquid chromatography; mass spectrometry; urine; veterinary controls; sports doping;
D O I
10.1016/j.aca.2006.09.058
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
A liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) method was developed using the latest high-resolution LC column technology, the ultra performance liquid chromatography (UPLC (TM)), and electrospray ionization (ESI) in the positive ion mode. Gradient UPLC separation conditions were optimized for a group of 22 analytes comprising 17 glucocorticosteroids, specific designer steroids such as tetrahydrogestrinone (THG) and specific beta(2)-agonists such as formoterol. The UPLC/TOFMS separation obtained required 5.5 min only for all the substances tested. Even the critical pair of dexamethasone and betamethasone isomers was almost completely resolved. Thanks to the over 10,000 full-width at half maximum (FWHM) mass resolution and high mass accuracy features of TOFMS 50 mDa window accurate mass chromatograms could be reconstructed for the individual analytes. Sensitive screening in human and calf urine samples fortified at the glucocorticosteroids minimum required performance limit (MRPL) of 30 mu g L(-1) (human urine, sports doping) and 2 mu g L-1 (calf urine, veterinary control) could be obtained. The potential of UPLC/TOFMS for confirmatory analysis was shown by determining the accurate mass of all compounds and fragment ions upon in-source collision-induced dissociation (CID) at different energies. The exact mass measurement errors for all glucocorticosteroids were found to be within 6 ppm. Considering veterinary control, limits of detection (LOD) and limits of quantification (LOQ) were determined for most of the analytes in calf urine and found to range from 0.1 to 3.3 and from 0.4 to 4.4 mu g L(-1), respectively. The method can be easily extended with other banned substances of interest, as demonstrated by the addition of 21 beta(2)-agonists to the original analyte mixture in urine, without causing any interferences. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:137 / 146
页数:10
相关论文
共 25 条
[1]
Simple liquid chromatography method for the rapid simultaneous determination of prednisolone and cortisol in plasma and urine using hydrophilic lipophilic balanced solid phase extraction cartridges [J].
AbuRuz, S ;
Millership, J ;
Heaney, L ;
McElnay, J .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 798 (02) :193-201
[2]
[Anonymous], OFF J EUR COMMUNIT L
[3]
Multi-residue extraction-purification procedure for corticosteroids in biological samples for efficient control of their misuse in livestock production [J].
Antignac, JP ;
Le Bizec, B ;
Monteau, F ;
Poulain, F ;
Andre, F .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 757 (01) :11-19
[4]
Determination of flumethasone in calf urine and serum by liquid chromatography-tandem mass spectrometry [J].
Brambilla, G ;
Buiarelli, F ;
Cartoni, GP ;
Coccioli, F ;
Colamonici, C ;
Fagiolo, A ;
Giannini, C ;
Neri, B .
JOURNAL OF CHROMATOGRAPHY B, 2001, 755 (1-2) :265-278
[5]
Comparison of dissociation of ions in an electrospray source, or a collision cell in tandem mass spectrometry [J].
Buré, C ;
Lange, C .
CURRENT ORGANIC CHEMISTRY, 2003, 7 (15) :1613-1624
[6]
Tetrahydrogestrinone: discovery, synthesis, and detection in urine [J].
Catlin, DH ;
Sekera, MH ;
Ahrens, BD ;
Starcevic, B ;
Chang, YC ;
Hatton, CK .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (12) :1245-1249
[7]
Quantitative determination of several synthetic corticosteroids by gas chromatography mass spectrometry after purification by immunoaffinity chromatography [J].
Delahaut, P ;
Jacquemin, P ;
Colemonts, Y ;
Dubois, M ;
DeGraeve, J ;
Deluyker, H .
JOURNAL OF CHROMATOGRAPHY B, 1997, 696 (02) :203-215
[8]
GREIG MJ, 2005, ANAL CHIM ACTA, V529, P361
[9]
Sensitive liquid chromatographic/tandem mass spectrometric method for the determination of beclomethasone dipropionate and its metabolites in equine plasma and urine [J].
Guan, FY ;
Uboh, C ;
Soma, L ;
Hess, A ;
Luo, Y ;
Tsang, DS .
JOURNAL OF MASS SPECTROMETRY, 2003, 38 (08) :823-838
[10]
Simultaneous analysis of twenty-one glucocorticoids in equine plasma by liquid chromatography/tandem mass spectrometry [J].
Luo, Y ;
Uboh, CE ;
Soma, LR ;
Guan, FY ;
Rudy, JA ;
Tsang, DS .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (10) :1245-1256