Elevated compartmental pressures after closure of a forearm burn wound with a skin-stretching device

被引:22
作者
Hussmann, J [1 ]
Kucan, JO [1 ]
Zamboni, WA [1 ]
机构
[1] SO ILLINOIS UNIV,SCH MED,INST RECONSTRUCT PLAST SURG,SPRINGFIELD,IL
关键词
D O I
10.1016/S0305-4179(96)00090-3
中图分类号
R4 [临床医学];
学科分类号
1002 [临床医学]; 100602 [中西医结合临床];
摘要
A case of successful delayed primary closure of an upper extremity electrical blow-out injury is described using nn alternative technique. The Sure-Closure skin-stretching device(1) tons used for permanent wound closure following serial debridement to protect the radial artery which was exposed over a distance of 21 cm. This method increases the options possible to achieve wound closure. However, the potential risks of this methods include potentially high compartment pressures oner a prolonged time in the postoperative period which requires close monitoring of limb perfusion. (C) 1997 Elsevier Science Ltd for ISBI.