Analytical method of estimating chemometric prediction error

被引:28
作者
Berger, AJ
Feld, MS
机构
[1] George R. Harrison Spectrosc. Lab., Massachusetts Inst. of Technology, Cambridge
关键词
chemometrics; PLS; spectroscopy; error analysis; uncertainty;
D O I
10.1366/0003702971940882
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present an analytical formula that estimates the uncertainty in concentrations predicted by linear multivariate calibration, particularly partial least-squares (PLS). We emphasize the analysis of spectroscopic data. The derivation addresses the important limit in which calibration error is negligible in comparison to noise in the prediction spectra. The formula is expressed in terms of standard PUS calibration parameters and the amplitude of spectral noise; it is therefore straightforward to evaluate. To test the formula, we performed PLS analysis upon simulated spectra and upon experimental Raman spectra of dissolved biological analytes in water. In each instance, the root-mean-squared error of prediction was compared to the estimate from the formula. Accurate uncertainty estimates were obtained in cases where calibration noise was lower than prediction noise, and surprisingly good estimates were obtained even when the noise levels were equal. By comparing measured and estimated uncertainties, we assessed the robustness of each PLS calibration model. The scaling of prediction uncertainty with the spectral signal-to-noise ratio is also discussed.
引用
收藏
页码:725 / 732
页数:8
相关论文
共 18 条
  • [1] [Anonymous], 1988, J CHEMOM, DOI DOI 10.1002/CEM.1180020203
  • [2] RAPID NEAR-INFRARED RAMAN-SPECTROSCOPY OF HUMAN TISSUE WITH A SPECTROGRAPH AND CCD DETECTOR
    BARAGA, JJ
    FELD, MS
    RAVA, RP
    [J]. APPLIED SPECTROSCOPY, 1992, 46 (02) : 187 - 190
  • [3] AQUEOUS DISSOLVED-GAS MEASUREMENTS USING NEAR-INFRARED RAMAN-SPECTROSCOPY
    BERGER, AJ
    WANG, Y
    SAMMETH, DM
    ITZKAN, I
    KNEIPP, K
    FELD, MS
    [J]. APPLIED SPECTROSCOPY, 1995, 49 (08) : 1164 - 1169
  • [4] Rapid, noninvasive concentration measurements of aqueous biological analytes by near-infrared Raman spectroscopy
    Berger, AJ
    Wang, Y
    Feld, MS
    [J]. APPLIED OPTICS, 1996, 35 (01): : 209 - 212
  • [5] BEVINGTON PR, 1969, DATA REDUCTION ERROR, P308
  • [6] BEVINGTON PR, 1969, DATA REDUCTION ERROR, P62
  • [7] BOOK SA, 1977, STAT BASIC TECHNIQUE, P122
  • [8] Durkin AJ, 1996, LASER SURG MED, V19, P75, DOI 10.1002/(SICI)1096-9101(1996)19:1<75::AID-LSM9>3.0.CO
  • [9] 2-N
  • [10] APPLICATION OF A MULTIVARIATE TECHNIQUE TO RAMAN-SPECTRA FOR QUANTIFICATION OF BODY CHEMICALS
    GOETZ, MJ
    COTE, GL
    ERCKENS, R
    MARCH, W
    MOTAMEDI, M
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (07) : 728 - 731