Performance analysis of an innovative small-scale trigeneration plant with liquid desiccant cooling system

被引:36
作者
Badami, M. [1 ]
Portoraro, A. [1 ]
机构
[1] Politecn Torino, Dipartimento Energet, Turin, Italy
关键词
Cogeneration; Trigeneration; Combined cooling heat and power (CHCP); Desiccant cooling; Dehumidification; Economic assessment; Energy market; COGENERATION SYSTEM; ENERGY; METHODOLOGY;
D O I
10.1016/j.enbuild.2009.06.006
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The paper deals with an innovative natural gas combined heat, cooling and power (CHCP) system with electrical, heating and cooling capacities of 126/220/210 kW, respectively. The trigeneration plant is composed of a cogenerator which uses an automotive derived gas fired internal combustion engine (ICE), coupled to a liquid LiCl-water desiccant cooling system which recovers heat from the flue gases and from the ICE cooling water. The paper describes the energetic and economic analyses of the plant and it makes some evaluations of the effects of fuel and electric prices and of the subsides and plant costs on the economic indices of the system. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1195 / 1204
页数:10
相关论文
共 18 条
[1]  
*ASHRAE, 2005, ASHRAE FUND HDB, pCH28
[2]  
*ASHRARE, 2005, ASHRAE FUND HDB, pCH22
[3]   Performance of an innovative 120kWe natural gas cogeneration system [J].
Badami, M. ;
Casetti, A. ;
Campanile, P. ;
Anzioso, F. .
ENERGY, 2007, 32 (05) :823-833
[4]   Energy saving in airports by trigeneration. Part I: Assessing economic and technical potential [J].
Cardona, E ;
Piacentino, A ;
Cardona, F .
APPLIED THERMAL ENGINEERING, 2006, 26 (14-15) :1427-1436
[5]   A new approach to exergoeconomic analysis and design of variable demand energy systems [J].
Cardona, E ;
Piacentino, A .
ENERGY, 2006, 31 (04) :490-515
[6]   A methodology for sizing a trigeneration plant in mediterranean areas [J].
Cardona, E ;
Piacentino, A .
APPLIED THERMAL ENGINEERING, 2003, 23 (13) :1665-1680
[7]   A measurement methodology for monitoring a CHCP pilot plant for an office building [J].
Cardona, E ;
Piacentino, A .
ENERGY AND BUILDINGS, 2003, 35 (09) :919-925
[8]   Trigeneration primary energy saving evaluation for energy planning and policy development [J].
Chicco, Gianfranco ;
Mancarella, Pierluigi .
ENERGY POLICY, 2007, 35 (12) :6132-6144
[9]   Desiccant cooling air conditioning: a review [J].
Daou, K ;
Wang, RZ ;
Xia, ZZ .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2006, 10 (02) :55-77
[10]  
IRVING G, 1978, COST BENEFIT METHODS