Percutaneous ablation therapy guided by contrast-enhanced sonography for patients with hepatocellular carcinoma

被引:55
作者
Numata, K
Isozaki, T
Ozawa, Y
Sakaguchi, T
Kiba, T
Kubota, T
Ito, A
Sugimori, K
Shirato, K
Morimoto, M
Tanaka, K
机构
[1] Yokohama City Univ, Sch Med, Clin Lab, Kanazawa Ku, Yokohama, Kanagawa 2360004, Japan
[2] Yokohama City Univ, Sch Med, Dept Internal Med 3, Yokohama, Kanagawa 2360004, Japan
[3] Yokohama City Univ, Sch Med, Dept Surg 2, Yokohama, Kanagawa 2360004, Japan
[4] Yokohama City Univ, Med Ctr, Gastroenterol Ctr, Yokohama, Kanagawa 2320024, Japan
关键词
D O I
10.2214/ajr.180.1.1800143
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The newly developed contrast-enhanced harmonic gray-scale sonography technique enables us to improve the real-time detectability of viable tumor tissue in hepatocellular carcinoma lesions. We evaluated the usefulness of real-time percutaneous ablation therapy under guidance with this method for patients with hepatocellular carcinoma that is not depicted on conventional sonography. SUBJECTS AND METHODS. We examined 30 patients with 56 hepatocellular carcinomas using real-time contrast-enhanced harmonic gray-scale sonography after injection of a galactose-palmitic acid contrast agent and compared the results with the findings of contrast-enhanced helical CT We performed percutaneous ablation therapy guided by this modality for treatment of viable hepatocellular carcinoma lesions that could not be detected using conventional sonography. RESULTS. High detection rates of viable hepatocellular carcinoma lesions were obtained using real-time contrast-enhanced harmonic gray-scale sonography (52/56 lesions, 93%); these rates were comparable to those of helical CT (54/56 lesions, 96%). Nine (90%) of the 10 lesions that were not detected on conventional sonography but were depicted on real-time contrast-enhanced harmonic gray-scale sonography (incomplete local treatment, n = 4; small new lesion, n = 6) were successfully treated with percutaneous ablation therapy guided by this method. CONCLUSION. Real-time contrast-enhanced harmonic gray-scale sonography improved the sensitivity for the detection of viable hepatocellular carcinoma lesions. Percutaneous ablation therapy guided by this modality may be useful in patients with hypervascular hepatocellular carcinoma lesions that cannot be detected using conventional sonography.
引用
收藏
页码:143 / 149
页数:7
相关论文
共 22 条
[1]  
Burns PN, 1996, CLIN RADIOL, V51, P50
[2]  
Child CG., 1954, HEPATIC CIRCULATION
[3]   Radiofrequency thermal ablation of hepatocellular carcinoma: Using contrast-enhanced harmonic power Doppler sonography to assess treatment outcome [J].
Cioni, D ;
Lencioni, R ;
Rossi, S ;
Garbagnati, F ;
Donati, F ;
Crocetti, L ;
Bartolozzi, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (04) :783-788
[4]   Hepatocellular carcinoma: Depiction of tumor parenchymal flow with intermittent harmonic power Doppler US during the early arterial phase in dual-display model [J].
Ding, H ;
Kudo, M ;
Onda, H ;
Suetomi, Y ;
Minami, Y ;
Maekawa, K .
RADIOLOGY, 2001, 220 (02) :349-356
[5]   Evaluation of posttreatment response of hepatocellular carcinoma with contrast-enhanced coded phase-inversion harmonic US: Comparison with dynamic CT [J].
Ding, H ;
Kudo, M ;
Onda, H ;
Suetomi, Y ;
Minami, Y ;
Chung, H ;
Kawasaki, T ;
Maekawa, K .
RADIOLOGY, 2001, 221 (03) :721-730
[6]   Contrast-enhanced subtraction harmonic sonography for evaluating treatment response in patients with hepatocellular carcinoma [J].
Ding, H ;
Kudo, M ;
Onda, H ;
Suetomi, Y ;
Minami, Y ;
Maekawa, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (03) :661-666
[7]   PERCUTANEOUS ETHANOL INJECTION FOR THE TREATMENT OF SMALL HEPATOCELLULAR-CARCINOMA - STUDY OF 95 PATIENTS [J].
EBARA, M ;
OHTO, M ;
SUGIURA, N ;
KITA, K ;
YOSHIKAWA, M ;
OKUDA, K ;
KONDO, F ;
KONDO, Y .
JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 1990, 5 (06) :616-626
[8]   Hepatic tumors: Contrast agent-enhancement patterns with pulse-inversion harmonic US [J].
Kim, TK ;
Choi, BI ;
Han, JK ;
Hong, HS ;
Park, SH ;
Moon, SG .
RADIOLOGY, 2000, 216 (02) :411-417
[9]   Gray scale second harmonic imaging of the liver: A preliminary animal study [J].
Kono, Y ;
Moriyasu, F ;
Nada, T ;
Suginoshita, Y ;
Matsumura, T ;
Kobayashi, K ;
Nakamura, T ;
Chiba, T .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (05) :719-726
[10]   Imaging diagnosis of hepatocellular carcinoma and premalignant/borderline lesions [J].
Kudo, M .
SEMINARS IN LIVER DISEASE, 1999, 19 (03) :297-309