Influence of repeated screw tightening on bacterial leakage along the implant-abutment interface

被引:43
作者
do Nascimento, Cassio [1 ]
Pedrazzi, Vinicius [1 ]
Miani, Paola Kirsten [1 ]
Moreira, Larissa Daher [1 ]
de Albuquerque Junior, Rubens Ferreira [1 ,2 ]
机构
[1] Univ Sao Paulo, Dept Dent Mat & Prosthodont, Fac Dent Ribeira Preto, BR-14040904 Sao Paulo, Brazil
[2] McGill Univ, Fac Dent, Quebec City, PQ, Canada
基金
巴西圣保罗研究基金会;
关键词
abutment screws; bacterial leakage; dental implants; DNA Checkerboard; DNA-DNA HYBRIDIZATION; IN-VITRO; CONTAMINATION; COMPONENTS; PROSTHESES; SYSTEMS; TORQUE; CAST;
D O I
10.1111/j.1600-0501.2009.01769.x
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
Objectives Bacterial penetration along the implant-abutment interface as a consequence of abutment screw loosening has been reported in a number of recent studies. The aim of this in vitro study was to investigate the influence of repeated tightening of the abutment screw on leakage of Streptococcus mutans along the interface between implants and pre-machined abutments. Materials and methods Twenty pre-machined abutments with a plastic sleeve were used. The abutment screws were tightened to 32 N cm in group 1 (n=10 - control) and to 32 N cm, loosened and re-tightened with the same torque twice in group 2 (n=10). The assemblies were completely immersed in 5 ml of Tryptic Soy Broth medium inoculated with S. mutans and incubated for 14 days. After this period, contamination of the implant internal threaded chamber was evaluated using the DNA Checkerboard method. Results Microorganisms were found on the internal surfaces of both groups evaluated. However, bacterial counts in group 2 were significantly higher than that in the control group (P < 0.05). Conclusion These results suggest that bacterial leakage between implants and abutments occurs even under unloaded conditions and at a higher intensity when the abutment screw is tightened and loosened repeatedly. To cite this article:do Nascimento C, Pedrazzi V, Kirsten Miani P, Daher Moreira L, de Albuquerque Junior RF. Influence of repeated screw tightening on bacterial leakage along the implant-abutment interface.Clin. Oral Impl. Res. 20, 2009; 1394-1397.doi: 10.1111/j.1600-0501.2009.01769.x.
引用
收藏
页码:1394 / 1397
页数:4
相关论文
共 22 条
[1]
BARBOSA RE, 2009, J PROSTHODONTICS
[2]
Brunski J B, 1988, Int J Oral Maxillofac Implants, V3, P85
[3]
Byrne Declan, 2006, J Prosthodont, V15, P164, DOI 10.1111/j.1532-849X.2006.00096.x
[4]
Bacterial leakage along the implant-abutment interface of premachined or cast components [J].
do Nascimento, C. ;
Barbosa, R. E. S. ;
Issa, J. P. M. ;
Watanabe, E. ;
Ito, I. Y. ;
Junior, R. F. Albuquerque .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2008, 37 (02) :177-180
[5]
The use of fluorescein for labeling genomic probes in the checkerboard DNA-DNA hybridization method [J].
do Nascimento, Cassio ;
Santos Barbosa, Rodrigo Edson ;
Mardegan Issa, Joao Paulo ;
Watanabe, Evandro ;
Ito, Izabel Yoko ;
Monesi, Nadia ;
de Albuquerque Junior, Rubens Ferreira .
MICROBIOLOGICAL RESEARCH, 2008, 163 (04) :403-407
[6]
Use of checkerboard DNA-DNA hybridization to evaluate the internal contamination of dental implants and comparison of bacterial leakage with cast or pre-machined abutments [J].
do Nascimento, Cassio ;
Santos Barbosa, Rodrigo Edson ;
Mardegan Issa, Joao Paulo ;
Watanabe, Evandro ;
Ito, Izabel Yoko ;
de Albuquerque, Rubens Ferreira, Jr. .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (06) :571-577
[7]
Clinical complications with implants and implant prostheses [J].
Goodacre, CJ ;
Bernal, G ;
Rungcharassaeng, K ;
Kan, JYK .
JOURNAL OF PROSTHETIC DENTISTRY, 2003, 90 (02) :121-132
[8]
Haack J E, 1995, Int J Oral Maxillofac Implants, V10, P529
[9]
Jansen VK, 1997, INT J ORAL MAX IMPL, V12, P527
[10]
A prospective 15-year follow-up study of mandibular fixed prostheses supported by osseointegrated implants - Clinical results and marginal bone loss [J].
Lindquist, LW ;
Carlsson, GE ;
Jemt, T .
CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (04) :329-336