摘要
In Norway there is a growing concern that electricity production and transmission may not meet the demand in peak-load situations. It is therefore important to evaluate the potential of different demand-side measures that may contribute to reduce peak load. This paper analyses data from an experiment where residential water heaters were automatically disconnected during peak periods of the day. A model of hourly electricity consumption is used to evaluate the effects on the load of the disconnections. The results indicate an average consumption reduction per household of approximately 0.5 kWh/h during disconnection, and an additional average increase in consumption the following hour, due to the payback effect, that may reach up to 0.28 kWh/h per household. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3502 / 3512
页数:11
相关论文
共 36 条
  • [1] AlZayer J, 1996, J FORECASTING, V15, P97, DOI 10.1002/(SICI)1099-131X(199603)15:2<97::AID-FOR608>3.0.CO
  • [2] 2-L
  • [3] [Anonymous], 2005, STAT STAT SOFTW REL
  • [4] DESIGN AND CONTROLLED USE OF WATER HEATER LOAD MANAGEMENT
    BISCHKE, RF
    SELLA, RA
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1985, 104 (06): : 1290 - 1293
  • [5] BYE T, 2005, ECON POLIT WEEKLY, V10, P5269
  • [6] *CHARL RIV ASS, 2003, DM PROGR INT EN
  • [7] GLENDE I, 2005, NORW SYST OP FAC TIG
  • [8] Gomes A, 1999, INT J ENERG RES, V23, P169, DOI 10.1002/(SICI)1099-114X(199902)23:2<169::AID-ER471>3.0.CO
  • [9] 2-P
  • [10] GOULD W, 2001, INTERPRETING INTERCE