Analysis of benzalkonium chloride in the effluent from European hospitals by solid-phase extraction and high-performance liquid chromatography with post-column ion-pairing and fluorescence detection

被引:119
作者
Kummerer, K
Eitel, A
Braun, U
Hubner, P
Daschner, F
Mascart, G
Milandri, M
Reinthaler, F
Verhoef, J
机构
[1] CTR HOSP NEW PAUL BRIEN,DEPT CLIN PATHOL,B-1030 BRUSSELS,BELGIUM
[2] OSPED MAGGIORE BOLOGNA,I-40133 BOLOGNA,ITALY
[3] INST HYG,A-8010 GRAZ,AUSTRIA
[4] ACAD ZIEKENHUIS,DEPT CLIN MICROBIOL,NL-3508 UTRECHT,NETHERLANDS
关键词
hospital effluent; derivatization; LC; fluorescence labelling; benzalkonium chloride; quaternary ammonium compounds; surfactants; disinfectants; dimethoxyanthracene-2-sulfonate;
D O I
10.1016/S0021-9673(97)00242-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly reproducible and specific method for the analysis of the quaternary ammonium compound, benzalkonium chloride, in effluents from European hospitals is presented. Benzalkonium chloride was extracted with end-capped RP-18 solid-phase cartridges and was selectively eluted. The resulting solution was analysed by high-performance liquid chromatography (HPLC). After elution from the analytical column of the HPLC system, 9,10-dimethoxyanthracene-2-sulfonate was added continuously as a fluorescence marker, forming a hydrophobic ion-pair with benzalkonium chloride. The ion-pair was analysed by fluorescence detection. The method was applied to highly complex effluent samples from different sized European hospitals. The measured concentrations were between 0.05 and 6.03 mg/l. The amounts emitted per bed and year were 4.5-362 g and did not correlate with the size of the hospital. The total amounts were 2.6-909 kg/year.
引用
收藏
页码:281 / 286
页数:6
相关论文
共 19 条
  • [1] ALAHMAD A, UNPUB
  • [2] BARANYAI A, 1994, ERW ZUS JAH 1994 HAM, V2, P844
  • [3] *BAY LEV, 1995, TECHN INF SHEET PREV
  • [4] DAUSCHNER F, 1996, PRAKTISCHE KRANKENHA
  • [5] LIQUID-CHROMATOGRAPHIC DETERMINATION OF CATIONIC SURFACTANTS IN ENVIRONMENTAL-SAMPLES USING A CONTINUOUS POSTCOLUMN ION-PAIR EXTRACTION DETECTOR WITH A SANDWICH PHASE SEPARATOR
    DERUITER, C
    HEFKENS, JCHF
    BRINKMAN, UAT
    FREI, RW
    EVERS, M
    MATTHIJS, E
    MEIJER, JA
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1987, 31 (2-4) : 325 - 339
  • [6] *EN ISO, 1996, GERM STAND METH EX W
  • [7] *EUR CTR EC TOX CH, 1993, DHTDMAC AQ TERR HAZ
  • [8] Contamination of hospital wastewater with hazardous compounds as defined by 7a WHG
    Gartiser, S
    Brinker, L
    Erbe, T
    Kümmerer, K
    Willmund, R
    [J]. ACTA HYDROCHIMICA ET HYDROBIOLOGICA, 1996, 24 (02): : 90 - 97
  • [9] SURFACTANT QUATERNARY AMMONIUM-SALTS IN AEROBIC SEWAGE DIGESTION
    GERIKE, P
    FISCHER, WK
    JASIAK, W
    [J]. WATER RESEARCH, 1978, 12 (12) : 1117 - 1122
  • [10] HULPKE H, 1993, ROMPP LEXIKON UMWELT, P703