Reliability of techniques to assess human neuromuscular function in vivo

被引:76
作者
Clark, Brian C. [1 ]
Cook, Summer B. [1 ]
Ploutz-Snyder, Lori L. [1 ]
机构
[1] Syracuse Univ, Dept Exercise Sci, Musculoskeletal Res Lab, Syracuse, NY 13244 USA
基金
美国国家航空航天局;
关键词
reliability; EMG; MRI; evoked force; H-reflex;
D O I
10.1016/j.jelekin.2005.11.008
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The purpose of this study was to comprehensively evaluate the reliability of a large number of commonly utilized experimental tests of in vivo human neuromuscular function separated by 4-weeks. Numerous electrophysiological parameters (i.e., voluntary and evoked electromyogram [EMG] signals), contractile properties (i.e., evoked forces and rates of force development and relaxation), muscle morphology (i.e., MRI-derived cross-sectional area [CSA]) and performance tasks (i.e., steadiness and time to task failure) were assessed from the plantarflexor muscle group in 17 subjects before and following 4-weeks where they maintained their normal lifestyle. The reliability of the measured variables had wide-ranging levels of consistency, with coefficient of variations (CV) ranging from similar to 2% to 20%, and intraclass correlation coefficients (ICC) between 0.53 and 0.99. Overall, we observed moderate to high-levels of reliability in the vast majority of the variables we assessed (24 out of the 29 had ICC > 0.70 and CV < 15%). The variables demonstrating the highest reliability were: CSA (ICC = 0.93-0.98), strength (ICC = 0.97), an index of nerve conduction velocity (ICC = 0.95), and H-reflex amplitude (ICC = 0.93). Conversely, the variables demonstrating the lowest reliability were: the amplitude of voluntary EMG signal (ICC = 0.53-0.88), and the time to task failure of a sustained submaximal contraction (ICC = 0.64). Additionally, relatively little systematic bias (calculated through the limits of agreement) was observed in these measures over the repeat sessions. In conclusion, while the reliability differed between the various measures, in general it was rather high even when the testing sessions are separated by a relatively long duration of time. (C) 2006 Published by Elsevier Ltd.
引用
收藏
页码:90 / 101
页数:12
相关论文
共 74 条
[1]   Neural adaptation to resistance training: changes in evoked V-wave and H-reflex responses [J].
Aagaard, P ;
Simonsen, EB ;
Andersen, JL ;
Magnusson, P ;
Dyhre-Poulsen, P .
JOURNAL OF APPLIED PHYSIOLOGY, 2002, 92 (06) :2309-2318
[2]   Increased rate of force development and neural drive of human skeletal muscle following resistance training [J].
Aagaard, P ;
Simonsen, EB ;
Andersen, JL ;
Magnusson, P ;
Dyhre-Poulsen, P .
JOURNAL OF APPLIED PHYSIOLOGY, 2002, 93 (04) :1318-1326
[3]  
Ali A, 2001, Electromyogr Clin Neurophysiol, V41, P209
[4]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[5]  
BASMAIJIAN JV, 1985, MUSCLE ALIVE THEIR F
[6]   Intermuscle differences in activation [J].
Behm, DG ;
Whittle, J ;
Button, D ;
Power, K .
MUSCLE & NERVE, 2002, 25 (02) :236-243
[7]   Fatigue characteristics following ankle fractures [J].
Behm, DG ;
StPierre, DMM .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1997, 29 (09) :1115-1123
[8]   CHANGES IN THE ELECTROMYOGRAPHIC SPECTRUM POWER DISTRIBUTION CAUSED BY A PROGRESSIVE INCREASE IN THE FORCE LEVEL [J].
BILODEAU, M ;
CINCERA, M ;
GERVAIS, S ;
ARSENAULT, AB ;
GRAVEL, D ;
LEPAGE, Y ;
MCKINLEY, P .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1995, 71 (2-3) :113-123
[9]   COMPARISON OF THE EMG POWER SPECTRUM OF THE HUMAN SOLEUS AND GASTROCNEMIUS-MUSCLES [J].
BILODEAU, M ;
GOULET, C ;
NADEAU, S ;
ARSENAULT, AB ;
GRAVEL, D .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1994, 68 (05) :395-401
[10]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310