Automatic Cobb Measurement of Scoliosis Based on Fuzzy Hough Transform with Vertebral Shape Prior

被引:68
作者
Zhang, Junhua [1 ]
Lou, Edmond [2 ]
Le, Lawrence H. [1 ]
Hill, Douglas L. [2 ]
Raso, James V. [2 ]
Wang, Yuanyuan [3 ]
机构
[1] Univ Alberta, Dept Radiol & Diagnost Imaging, Edmonton, AB T6G 2E1, Canada
[2] Glenrose Rehabil Hosp, Dept Rehabil Technol, Edmonton, AB T5G 0B7, Canada
[3] Fudan Univ, Dept Elect Engn, Shanghai 200433, Peoples R China
关键词
Cobb angle; scoliosis; fuzzy Hough transform (FHT); shape prior; radiograph; ADOLESCENT IDIOPATHIC SCOLIOSIS; EDGE-DETECTION; ANGLE;
D O I
10.1007/s10278-008-9127-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
To reduce variability of Cobb angle measurement for scoliosis assessment, a computerized method was developed. This method automatically measured the Cobb angle on spinal posteroanterior radiographs after the brightness and the contrast of the image were adjusted, and the top and bottom of the vertebrae were selected. The automated process started with the edge detection of the vertebra by Canny edge detector. After that, the fuzzy Hough transform was used to find line structures in the vertebral edge images. The lines that fitted to the endplates of vertebrae were identified by selecting peaks in Hough space under the vertebral shape constraints. The Cobb angle was then calculated according to the directions of these lines. A total of 76 radiographs were respectively analyzed by an experienced surgeon using the manual measurement method and by two examiners using the proposed method twice. Intraclass correlation coefficients (ICC) showed high agreement between automatic and manual measurements (ICCs > 0.95). The mean absolute differences between automatic and manual measurements were less than 5A degrees. In the interobserver analyses, ICCs were higher than 0.95, and mean absolute differences were less than 5A degrees. In the intraobserver analyses, ICCs were 0.985 and 0.978, respectively, for each examiner, and mean absolute differences were less than 3A degrees. These results demonstrated the validity and reliability of the proposed method.
引用
收藏
页码:463 / 472
页数:10
相关论文
共 18 条
[1]
ALLEN S, 2007, J DIGIT IMAGING, P1
[2]
[Anonymous], 1948, AM ACAD ORTHOP SURG
[4]
Computer-assisted Cobb measurement of scoliosis [J].
Chockalingam, N ;
Dangerfield, PH ;
Giakas, G ;
Cochrane, T ;
Dorgan, JC .
EUROPEAN SPINE JOURNAL, 2002, 11 (04) :353-357
[5]
Currier D., 1990, Elements of research in physical therapy, V3rd
[6]
USE OF HOUGH TRANSFORMATION TO DETECT LINES AND CURVES IN PICTURES [J].
DUDA, RO ;
HART, PE .
COMMUNICATIONS OF THE ACM, 1972, 15 (01) :11-&
[7]
Greiner KA, 2002, AM FAM PHYSICIAN, V65, P1817
[8]
FUZZY HOUGH TRANSFORM [J].
HAN, JH ;
KOCZY, LT ;
POSTON, T .
PATTERN RECOGNITION LETTERS, 1994, 15 (07) :649-658
[9]
Hough PVC, 1962, U.S. Patent, Patent No. 3069654
[10]
Adolescent idiopathic scoliosis [J].
Lenke, LG ;
Betz, RR ;
Harms, J ;
Bridwell, KH ;
Clements, DH ;
Lowe, TG ;
Blanke, K .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (08) :1169-1181