Repeatability of corneal thickness measurements made by a scanning slit topography system

被引:23
作者
Cho, P [1 ]
Cheung, SW [1 ]
机构
[1] Hong Kong Polytech Univ, Ctr Myopia Res, Dept Optometry & Radiog, Kowloon, Hong Kong, Peoples R China
关键词
central cornea; corneal thickness; Orbscan; peripheral cornea; repeatability;
D O I
10.1046/j.1475-1313.2002.00060.x
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
Two sets of corneal thickness (CT) measurements at five corneal locations were made with Orbscan on 33 normal young adults. No significant intravisit and intervisit differences at any of the corneal locations were found (Repeated measures ANOVA, F < 0.49, p > 0.49). The 95% limits of agreement (95% LA) for between-measurement differences for the central cornea was about +/-19 mum (or 3%), indicating good repeatability; for the inferior, temporal and nasal corneal locations, the 95% LA were close to +/-30 mum (approximate to4-5%); and for the superior corneal location, they were about +/-35 mum (or 5.5%). The estimated number of repeated measurements that should be taken for accurate CT measurements (at any of the five corneal locations and excluding outliers of >3 S.D.) of 2% (standard error) is less than or equal to2, and of 3% is 1. This study shows that only central CT measurements with the Orbscan are repeatable. The role of the Orbscan pachometry is therefore limited and is recommended for central CT measurements only.
引用
收藏
页码:505 / 510
页数:6
相关论文
共 26 条
[1]
Ocular hypertension and central corneal thickness [J].
Argus, WA .
OPHTHALMOLOGY, 1995, 102 (12) :1810-1812
[2]
Avitabile T, 1997, CORNEA, V16, P639
[3]
Factors affecting the forward shift of posterior corneal surface after laser in situ keratomileusis [J].
Baek, TM ;
Lee, KH ;
Kagaya, F ;
Tomidokoro, A ;
Amano, S ;
Oshika, T .
OPHTHALMOLOGY, 2001, 108 (02) :317-320
[4]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]
Comparison of corneal thickness measurements using ultrasound and Orbscan slit-scanning topography in normal and post-LASIK eyes [J].
Chakrabarti, HS ;
Craig, JP ;
Brahma, A ;
Malik, TY ;
McGhee, CNJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (11) :1823-1828
[6]
Central and peripheral corneal thickness measured with the TOPCON specular microscope SP-2000P [J].
Cho, P ;
Cheung, SW .
CURRENT EYE RESEARCH, 2000, 21 (04) :799-807
[7]
RELATIVE SENSITIVITY OF CLINICAL-TESTS TO HYDROPHILIC LENS-INDUCED CORNEAL THICKNESS CHANGES [J].
ELLIOTT, DB ;
FONN, D ;
FLANAGAN, J ;
DOUGHTY, M .
OPTOMETRY AND VISION SCIENCE, 1993, 70 (12) :1044-1048
[8]
CHANGES IN REFRACTIVE TRENDS AND OPTICAL-COMPONENTS OF HONG-KONG CHINESE AGED 19-39 YEARS [J].
GOH, WSH ;
LAM, CSY .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1994, 14 (04) :378-382
[9]
Gritz D C, 1990, Refract Corneal Surg, V6, P9
[10]
Central corneal thickness in normal, glaucomatous, and ocular hypertensive eyes [J].
Herndon, LW ;
Choudhri, SA ;
Cox, T ;
Damji, KF ;
Shields, MB ;
Allingham, RR .
ARCHIVES OF OPHTHALMOLOGY, 1997, 115 (09) :1137-1141