A comparison of simulated difficult intubation with multiple-use and single-use bougies in a manikin

被引:51
作者
Annamaneni, R [1 ]
Hodzovic, I [1 ]
Wilkes, AR [1 ]
Latto, IP [1 ]
机构
[1] Univ Wales Hosp, Cardiff CF14 4XW, S Glam, Wales
关键词
equipment; gum-elastic bougie; intubation; tracheal;
D O I
10.1046/j.1365-2044.2003.02871.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
In a randomised cross-over study, 20 anaesthetists attempted to place a multiple- or single-use bougie in the trachea of a manikin, in which a grade 3 Cormack and Lehane laryngoscopic view was simulated. The anaesthetists made two attempts at placement with each bougie and were blinded to success (tracheal placement) or failure (oesophageal placement). The success rates for the first attempts with the multiple- and single-use bougies were 85 and 15%, respectively [mean (95% CI) difference between the two bougies 70% (40-84%); p < 0.001]. The success rates for the second attempts were similar to those for the first attempts with both bougies. There is an increased risk of failure to intubate the trachea when using a single-use bougie, and this must be weighed against the unquantified risk of cross-infection from prions when using a multiple-use bougie.
引用
收藏
页码:45 / 49
页数:5
相关论文
共 14 条
[1]   A new practical classification of laryngeal view [J].
Cook, TM .
ANAESTHESIA, 2000, 55 (03) :274-279
[2]   DIFFICULT TRACHEAL INTUBATION IN OBSTETRICS [J].
CORMACK, RS ;
LEHANE, J .
ANAESTHESIA, 1984, 39 (11) :1105-1111
[3]   Microbial contamination of gum elastic bougies [J].
Cupitt, JM .
ANAESTHESIA, 2000, 55 (05) :466-468
[4]   Simulated difficult intubation - Comparison of the gum elastic bougie and the stylet [J].
Gataure, PS ;
Vaughan, RS ;
Latto, IP .
ANAESTHESIA, 1996, 51 (10) :935-938
[5]   Diagnosis of new variant Creutzfeldt-Jakob disease by tonsil biopsy [J].
Hill, AF ;
Zeidler, M ;
Ironside, J ;
Collinge, J .
LANCET, 1997, 349 (9045) :99-100
[6]  
HUTTON P, 2002, ROYAL COLL ANAESTHET, V12, P555
[7]   Survey of the use of the gum elastic bougie in clinical practice [J].
Latto, IP ;
Stacey, M ;
Mecklenburgh, J ;
Vaughan, RS .
ANAESTHESIA, 2002, 57 (04) :379-384
[8]  
*MED DEV AG, 2001, MDA SAF WARN HN20010
[9]   Presence of protein deposits on 'cleaned' re-usable anaesthetic equipment [J].
Miller, DM ;
Youkhana, I ;
Karunaratne, WU ;
Pearce, A .
ANAESTHESIA, 2001, 56 (11) :1069-1072
[10]   Difficult airway equipment in departments English emergency departments [J].
Morton, T ;
Brady, S ;
Clancy, M .
ANAESTHESIA, 2000, 55 (05) :485-488