External flow effects on the discharge coefficients of two types of ventilation opening

被引:51
作者
Chiu, Y-H.
Etheridge, D. W.
机构
[1] Univ Nottingham, Sch Built Environm, Nottingham NG7 2RD, England
[2] Chinese Culture Univ, Dept Architecture & Urban Design, Taipei, Taiwan
基金
英国工程与自然科学研究理事会;
关键词
natural ventilation; discharge coefficient; wind tunnel modelling; chimney;
D O I
10.1016/j.jweia.2006.06.013
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Envelope flow models are commonly used in the design of naturally ventilated buildings. Such models rely on specification of the discharge coefficient, C-z of ventilation openings, such as air vents and chimneys (stacks). Current practice is to make use of values obtained from laboratory tests under still-air conditions. These values may not be appropriate when the ventilation is due to wind, due to the external flow around the opening which is characterized by unsteadiness of both the velocity and pressure fields. Experimental tests have been carried out in a wind tunnel on two types of openings, namely a sharp-edged orifice (flush to the wall) and a long opening (chimney). Using an analytic result for the still-air case and simple dimensional analysis it is argued that the local crossflow velocity ratio, V/u, is an important parameter for the orifice and the experimental results support this (as do some simple CFD calculations). The experimental results for the sharp-edged opening are similar to earlier work on generally larger openings. For the long opening the effects of external flow are smaller. In particular, the effects are negligible when the outlet of the opening lies in the external flow. Estimates are made of the consequential uncertainties arising in envelope flow calculations for natural ventilation design. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:225 / 252
页数:28
相关论文
共 14 条
[1]  
[Anonymous], INT J VENT
[2]  
[Anonymous], INT J VENT
[3]  
Carey P.S., 1999, BUILD SERV ENG RES T, V20, P131, DOI [10.1177/014362449902000305, DOI 10.1177/014362449902000305]
[4]   Experimental technique to determine unsteady flow in natural ventilation stacks at model scale [J].
Chiu, YH ;
Etheridge, DW .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2004, 92 (3-4) :291-313
[5]  
Etheridge D., 1996, Building ventilation: theory and measurement
[6]   Nondimensional methods for natural ventilation design [J].
Etheridge, DW .
BUILDING AND ENVIRONMENT, 2002, 37 (11) :1057-1072
[7]   VENTILATION MEASUREMENTS AT MODEL SCALE IN A TURBULENT-FLOW [J].
ETHERIDGE, DW ;
NOLAN, JA .
BUILDING AND ENVIRONMENT, 1979, 14 (01) :53-64
[8]  
Idelchik IE, 1986, HDB HYDRAULIC RESIST
[9]  
Karava P., 2004, International Journal of Ventilation, V3, P255, DOI DOI 10.1080/14733315.2004.11683920
[10]  
Kurabuchi T., 2004, Int. J. Vent., V2, P371