Novel amperometric biosensor based on composite film assembled by polyelectrolyte-surfactant polymer, carbon nanotubes and hemoglobin

被引:50
作者
Chen, Liang
Lu, Gongxuan [1 ]
机构
[1] Chinese Acad Sci, Lanzhou Inst Chem Phys, State Key Lab Oxo Synth & Select Oxidat, Lanzhou 730000, Peoples R China
[2] Chinese Acad Sci, Grad Sch, Beijing 100080, Peoples R China
关键词
biosensor; hydrogen peroxide; composite; hemoglobin; carbon nanotube; polyelectrolyte-surfactant;
D O I
10.1016/j.snb.2006.04.067
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel hydrogen peroxide biosensor has been developed based on the encapsulation of hemoglobin (Hb) in the composite film of carboxylic carbon nanotubes and polyelectrolyte-surfactant polymer. The direct electron transfer of the Hb entrapped in the composite film was observed. The formal potential of the encapsulated Hb was -0.287 V versus SCE and the heterogeneous electron transfer rate constant was 0.4 s(-1) in a 0.1 M phosphate buffer solution (pH 7.0). An FT-IR spectroscopy study confirms that the secondary structure of Hb encapsulated in the composite film still retains the original arrangement. It is suggested that the achieved faradic response of the hemoglobin be due to the promotion properties of carbon nanotube in electron transfer in biomembrane-like polyelectrolyte-surfactant polymer. The entrapped Hb exhibited excellent electrocatalytic activity to reduce hydrogen peroxide. The properties of functional composite film, together with the bioelectrochemical catalytic activity, could make them useful in the development of bioelectronic devices and investigation of protein electrochemistry at functional interface. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:423 / 429
页数:7
相关论文
共 25 条
[1]   Nanotubes from carbon [J].
Ajayan, PM .
CHEMICAL REVIEWS, 1999, 99 (07) :1787-1799
[2]   Direct electron transfer and bioelectrocatalysis of hemoglobin at a carbon nanotube electrode [J].
Cai, CX ;
Chen, J .
ANALYTICAL BIOCHEMISTRY, 2004, 325 (02) :285-292
[3]   Solution properties of single-walled carbon nanotubes [J].
Chen, J ;
Hamon, MA ;
Hu, H ;
Chen, YS ;
Rao, AM ;
Eklund, PC ;
Haddon, RC .
SCIENCE, 1998, 282 (5386) :95-98
[4]   Electron-transfer reactivity and enzymatic activity of hemoglobin in a SP sephadex membrane [J].
Fan, CH ;
Wang, HY ;
Sun, S ;
Zhu, DX ;
Wagner, G ;
Li, GX .
ANALYTICAL CHEMISTRY, 2001, 73 (13) :2850-2854
[5]   Amperometric biosensors based on redox polymer-carbon nanotube-enzyme composites [J].
Joshi, PP ;
Merchant, SA ;
Wang, YD ;
Schmidtke, DW .
ANALYTICAL CHEMISTRY, 2005, 77 (10) :3183-3188
[6]   ROTATING-RING-DISK ENZYME ELECTRODE FOR BIOCATALYSIS KINETIC-STUDIES AND CHARACTERIZATION OF THE IMMOBILIZED ENZYME LAYER [J].
KAMIN, RA ;
WILSON, GS .
ANALYTICAL CHEMISTRY, 1980, 52 (08) :1198-1205
[7]   GENERAL EXPRESSION OF THE LINEAR POTENTIAL SWEEP VOLTAMMOGRAM IN THE CASE OF DIFFUSIONLESS ELECTROCHEMICAL SYSTEMS [J].
LAVIRON, E .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1979, 101 (01) :19-28
[8]   Direct electrochemistry of hemoglobin in biomembrane-like DHP-PDDA polyion-surfactant composite films [J].
Liu, HY ;
Wang, LW ;
Hu, NF .
ELECTROCHIMICA ACTA, 2002, 47 (15) :2515-2523
[9]   Electrochemical reduction and voltammetric determination of metronidazole at a nanomaterial thin film coated glassy carbon electrode [J].
Lu, SF ;
Wu, KB ;
Dang, XP ;
Hu, SS .
TALANTA, 2004, 63 (03) :653-657
[10]   Self assembled polyelectrolyte - Surfactant complexes in nonaqueous solvents and in the solid state [J].
MacKnight, WJ ;
Ponomarenko, EA ;
Tirrell, DA .
ACCOUNTS OF CHEMICAL RESEARCH, 1998, 31 (12) :781-788