Diffusion-tensor MRI: theory, experimental design and data analysis - a technical review

被引:1093
作者
Basser, PJ [1 ]
Jones, DK
机构
[1] NICHD, Sect Tissue Biophys & Biomimet, NIH, Bethesda, MD 20892 USA
[2] Inst Psychiat, Sect Old Psychiat, London, England
关键词
diffusion; tensor; MRI; methods;
D O I
10.1002/nbm.783
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This article treats the theoretical underpinnings of diffusion-tensor magnetic resonance imaging (DT-MRI), as well as experimental design and data analysis issues. We review the mathematical model underlying DT-MRI, discuss the quantitative parameters that are derived from the measured effective diffusion tensor, and describe artifacts thet arise in typical DT-MRI acquisitions. We also discuss difficulties in identifying appropriate models to describe water diffusion in heterogeneous tissues, as well as in interpreting experimental data obtained in such issues. Finally, we describe new statistical methods that have been developed to analyse DT-MRI data, and their potential uses in clinical and multi-site studies. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:456 / 467
页数:12
相关论文
共 118 条
  • [1] MR microscopy of transgenic mice that spontaneously acquire experimental allergic encephalomyelitis
    Ahrens, ET
    Laidlaw, DH
    Readhead, C
    Brosnan, CF
    Fraser, SE
    Jacobs, RE
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (01) : 119 - 132
  • [2] Aldroubi A., 1999, CONT MATH, V247, P1, DOI [10.1090/conm/247/03794, DOI 10.1090/CONM/247/03794]
  • [3] Alexander AL, 2000, MAGNET RESON MED, V44, P283, DOI 10.1002/1522-2594(200008)44:2<283::AID-MRM16>3.0.CO
  • [4] 2-V
  • [5] Elimination of eddy current artifacts in diffusion-weighted echo-planar images: The use of bipolar gradients
    Alexander, AL
    Tsuruda, JS
    Parker, DL
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (06) : 1016 - 1021
  • [6] ALEXANDER DC, IEEE T MED IMAG, V20, P1131
  • [7] ANALYSIS AND CORRECTION OF MOTION ARTIFACTS IN-DIFFUSION WEIGHTED IMAGING
    ANDERSON, AW
    GORE, JC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) : 379 - 387
  • [8] Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using Sensitivity Encoding (SENSE)
    Bammer, R
    Keeling, SL
    Augustin, M
    Pruessmann, KP
    Wolf, R
    Stollberger, R
    Hartung, HP
    Fazekas, F
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) : 548 - 554
  • [9] Basser P.J., 1999, ISMRM, P1788
  • [10] Basser PJ, 2000, MAGNET RESON MED, V44, P625, DOI 10.1002/1522-2594(200010)44:4<625::AID-MRM17>3.0.CO