Background-Ablation of complex arrhythmias would be greatly facilitated by more precise control of ablation catheters. A feasibility study was performed in animals to evaluate a novel magnetic guidance system (MGS) that generates a magnetic field to control the movement and position of a magnetic ablation catheter. Methods and Results-The MGS is composed of a digital biplanar fluoroscope within an array of superconducting electromagnets that surround the torso of the experimental animal and a computer control system that generates a composite magnetic field for directional catheter deflection. Magnetic catheter navigation was performed in dogs and pigs (20 to 30 kg). A 7F magnetic ablation catheter was used for intracardiac navigation and radiofrequency ablation. The performance of a standard 7F deflectable catheter was not affected by the MGS. The magnetic catheter was navigated successfully to 51 predefined targets throughout the heart in 6 animals. In 5 animals, the magnetic catheter, guided by a 3D computed tomogram, was successfully navigated to all pulmonary veins. Navigation accuracy was estimated as < 1 mm displacement from the target. The magnetic catheter was used to ablate the atrioventricular node in 4 animals and to perform linear ablations across the endocardial surface underlying an epicardial multielectrode recording plaque in 4 animals. Conclusions-These results demonstrate that the MGS can navigate and stabilize an ablation catheter at endocardial targets. Linear or focal radiofrequency ablation with the magnetic catheter is not compromised by the magnetic field. This technology provides precise control of endocardial catheters.
引用
收藏
页码:2980 / 2985
页数:6
相关论文
共 11 条
  • [1] DIAGNOSIS AND CURE OF THE WOLFF-PARKINSON-WHITE SYNDROME OR PAROXYSMAL SUPRAVENTRICULAR TACHYCARDIAS DURING A SINGLE ELECTROPHYSIOLOGIC TEST
    CALKINS, H
    SOUSA, J
    ELATASSI, R
    ROSENHECK, S
    DEBUITLEIR, M
    KOU, WH
    KADISH, AH
    LANGBERG, JJ
    MORADY, F
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (23) : 1612 - 1618
  • [2] OPTIMIZING ELECTROCARDIOGRAPH ELECTRODE PLACEMENT FOR CARDIAC-GATED MAGNETIC-RESONANCE-IMAGING
    DIMICK, RN
    HEDLUND, LW
    HERFKENS, RJ
    FRAM, EK
    UTZ, J
    [J]. INVESTIGATIVE RADIOLOGY, 1987, 22 (01) : 17 - 22
  • [3] RADIOFREQUENCY CATHETER ABLATION FOR THE TREATMENT OF HUMAN TYPE-1 ATRIAL-FLUTTER - IDENTIFICATION OF A CRITICAL ZONE IN THE REENTRANT CIRCUIT BY ENDOCARDIAL MAPPING TECHNIQUES
    FELD, GK
    FLECK, RP
    CHEN, PS
    BOYCE, K
    BAHNSON, TD
    STEIN, JB
    CALISI, CM
    IBARRA, M
    [J]. CIRCULATION, 1992, 86 (04) : 1233 - 1240
  • [4] Catheter ablation of chronic atrial fibrillation targeting the reinitiating triggers
    Haïssaguerre, M
    Jaïs, P
    Shah, DC
    Arentz, T
    Kalusche, D
    Takahashi, A
    Garrigue, S
    Hocini, M
    Peng, JT
    Clémenty, J
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (01) : 2 - 10
  • [5] CATHETER ABLATION OF ACCESSORY ATRIOVENTRICULAR PATHWAYS (WOLFF-PARKINSON-WHITE SYNDROME) BY RADIOFREQUENCY CURRENT
    JACKMAN, WM
    WANG, XZ
    FRIDAY, KJ
    ROMAN, CA
    MOULTON, KP
    BECKMAN, KJ
    MCCLELLAND, JH
    TWIDALE, N
    HAZLITT, HA
    PRIOR, MI
    MARGOLIS, PD
    CALAME, JD
    OVERHOLT, ED
    LAZZARA, R
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (23) : 1605 - 1611
  • [6] TREATMENT OF SUPRAVENTRICULAR TACHYCARDIA DUE TO ATRIOVENTRICULAR NODAL REENTRY BY RADIOFREQUENCY CATHETER ABLATION OF SLOW-PATHWAY CONDUCTION
    JACKMAN, WM
    BECKMAN, KJ
    MCCLELLAND, JH
    WANG, XZ
    FRIDAY, KJ
    ROMAN, CA
    MOULTON, KP
    TWIDALE, N
    HAZLITT, HA
    PRIOR, MI
    OREN, J
    OVERHOLT, ED
    LAZZARA, R
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1992, 327 (05) : 313 - 318
  • [7] First human experience with pulmonary vein isolation using a through-the-balloon circumferential ultrasound ablation system for recurrent atrial fibrillation
    Natale, A
    Pisano, E
    Shewchik, J
    Bash, D
    Fanelli, R
    Potenza, D
    Santarelli, P
    Schweikert, R
    White, R
    Saliba, W
    Kanagaratnam, L
    Tchou, P
    Lesh, M
    [J]. CIRCULATION, 2000, 102 (16) : 1879 - 1882
  • [8] CATHETER ABLATION USING RADIOFREQUENCY CURRENT TO CURE SYMPTOMATIC PATIENTS WITH TACHYARRHYTHMIAS RELATED TO AN ACCESSORY ATRIOVENTRICULAR PATHWAY
    SCHLUTER, M
    GEIGER, M
    SIEBELS, J
    DUCKECK, W
    KUCK, KH
    [J]. CIRCULATION, 1991, 84 (04) : 1644 - 1661
  • [9] IDENTIFICATION OF REENTRY CIRCUIT SITES DURING CATHETER MAPPING AND RADIOFREQUENCY ABLATION OF VENTRICULAR-TACHYCARDIA LATE AFTER MYOCARDIAL-INFARCTION
    STEVENSON, WG
    KHAN, H
    SAGER, P
    SAXON, LA
    MIDDLEKAUFF, HR
    NATTERSON, PD
    WIENER, I
    [J]. CIRCULATION, 1993, 88 (04) : 1647 - 1670
  • [10] Anatomic substrate for idiopathic left ventricular tachycardia
    Thakur, RK
    Klein, GJ
    Sivaram, CA
    Zardini, M
    Schleinkofer, DE
    Nakagawa, H
    Yee, R
    Jackman, WM
    [J]. CIRCULATION, 1996, 93 (03) : 497 - 501