Assessment of gadobenate dimeglumine for magnetic resonance angiography - Phase I studies

被引:51
作者
Knopp, MV
Schoenberg, SO
Rehm, C
Floemer, F
Von Tengg-Kobligk, H
Bock, M
Hentrich, HR
机构
[1] Ohio State Univ Hosp, Dept Radiol, Columbus, OH 43210 USA
[2] German Canc Res Ctr, Dept Radiol, Heidelberg, Germany
[3] Bracco Byk Gulden, Constance, Germany
关键词
contrast media; comparative studies; intraindividual; MR angiography; Gd-BOPTA; phase I studies;
D O I
10.1097/00004424-200212000-00011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. To assess the vascular contrasting properties of a new MR contrast agent (gadobenate dimeglumine [Gd-BOPTA]), which presents higher relaxivity because of reversible, weak protein interaction, and, to compare these properties with a standard gadolinium agent. MATERIALS AND METHODS. Two phase I trials compared intraindividually: (A) the vascular contrasting properties of Gd-BOPTA at three doses (0.0125, 0.05, and 0.2 mmol/kg body weight) and two flow rates (0.5 and 2.0 mL/s) in 10 volunteers; and (B) 0.1 mmol/kg body weight doses of Gd-BOPTA and Gd-DTPA at 2.0 mL/s using a modified magnetic resonance angiography (MRA) sequence with a temporal resolution of 1 s/f. Quantitative (ROI analysis) and fully blinded qualitative (reader review) assessment of images was performed. RESULTS. A dose of 0.2 mmol/kg resulted in higher maximum intensities, longer median peak widths, and larger areas under the curve than did the lower doses (0.0125 mmol/kg and 0.05 mmol/kg). In the intraindividual comparison, Gd-BOPTA demonstrated significantly better vascular enhancement characteristics in terms of signal peak duration (p < 0.05), maximum signal intensity (p < 0.05), and area under the enhancement curve (p < 0.01). The multireader assessment for overall vascular contrast preferred Gd-BOPTA at p < 0.03. CONCLUSIONS. Gd-BOPTA was shown to exhibit preferential and different vascular enhancement properties as compared with Gd-DTPA for MRA.
引用
收藏
页码:706 / 715
页数:10
相关论文
共 36 条
[1]   Optimization of scantiming in abdominal breathhold contrast-enhanced MRA: an empirical guideline [J].
Boeve, WJ ;
Sluiter, WJ ;
Kamman, RL .
MAGNETIC RESONANCE IMAGING, 2001, 19 (02) :193-200
[2]   Contrast-enhanced magnetic resonance angiography of peripheral vessels - Different contrast agent applications and sequence strategies: A review [J].
Boos, M ;
Lentschig, M ;
Scheffler, K ;
Bongartz, GM ;
Steinbrich, W .
INVESTIGATIVE RADIOLOGY, 1998, 33 (09) :538-546
[3]   Arterial first pass gadolinium-CM dynamics as a function of several intravenous saline flush and Gd volumes [J].
Boos, M ;
Scheffler, K ;
Haselhorst, R ;
Reese, E ;
Fröhlich, J ;
Bongartz, GM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (04) :568-576
[4]   The effect of injection rate on time-resolved contrast-enhanced peripheral MRA [J].
Carroll, TJ ;
Korosec, FR ;
Swan, JS ;
Hany, TF ;
Grist, TM ;
Mistretta, CA .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (04) :401-410
[5]   Gadolinium chelates with weak binding to serum proteins - A new class of high-efficiency, general purpose contrast agents for magnetic resonance imaging [J].
Cavagna, FM ;
Maggioni, F ;
Castelli, PM ;
Dapra, M ;
Imperatori, LG ;
Lorusso, V ;
Jenkins, BG .
INVESTIGATIVE RADIOLOGY, 1997, 32 (12) :780-796
[6]   BINDING OF GADOBENATE DIMEGLUMINE TO PROTEINS EXTRAVASATED INTO INTERSTITIAL SPACE ENHANCES CONSPICUOUSNESS OF REPERFUSED INFARCTS [J].
CAVAGNA, FM ;
MARZOLA, P ;
DAPRA, M ;
MAGGIONI, F ;
VICINANZA, E ;
CASTELLI, PM ;
DEHAEN, C ;
LUCHINAT, C ;
WENDLAND, MF ;
SAEED, M ;
HIGGINS, CB .
INVESTIGATIVE RADIOLOGY, 1994, 29 :S50-S53
[7]  
*CPMP ICH, 1996, GUID GOOD CLIN PRACT
[8]   Pharmacokinetics and safety of gadobenate dimeglumine (Multihance) in subjects with impaired liver function [J].
Davies, BE ;
Kirchin, MA ;
Bensel, K ;
Lorusso, V ;
Davies, A ;
Parker, JR ;
Lafrance, ND .
INVESTIGATIVE RADIOLOGY, 2002, 37 (05) :299-308
[9]   Gadobenate dimeglumine 0.5 M solution for injection (MultiHance®):: Pharmaceutical formulation and physicochemical properties of a new magnetic resonance imaging contrast medium [J].
de Haën, C ;
Cabrini, M ;
Akhnana, L ;
Ratti, D ;
Calabi, L ;
Gozzini, L .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 :S161-S168
[10]   MR-based assessment of vascular morphology and function [J].
Debatin, JF ;
Hany, TF .
EUROPEAN RADIOLOGY, 1998, 8 (04) :528-539