Flow-through cell based on an array of gold microelectrodes obtained from modified integrated circuit chips

被引:26
作者
Augelli, MA
Nascimento, VB
Pedrotti, JJ
Gutz, IGR
Angnes, L
机构
[1] UNESP,FAC ENGN GUARATINGUETA,SAO PAULO,BRAZIL
[2] UNIV FED RURAL PERNAMBUCO,DEPT QUIM,RECIFE,PE,BRAZIL
关键词
flow-through cell; gold microelectrode array; integrated circuit chips; reverse pulse amperometry; flow injection analysis;
D O I
10.1039/a701519d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The construction of a flow-through cell incorporating an array of gold microelectrodes is described and its application to flow injection analysis with amperometric detection is presented, Simple modification of almost any conventional integrated circuit chip, used as an inexpensive source of pre-assembled gold micro-wires, leads to the rapid and successful preparation of arrays of 8-48 elements, The polymeric encapsulation material from the top face of the chip is removed by abrasion until the gold micro-mires (used to interconnect the silicon circuit to the external contact pins of the chip) are disrupted and their transversal (elliptical) sections become exposed. Once polished, the flat and smooth top surface of the gold microelectrode-array chip (MEAC) is provided with a spacer and fitted under pressure against an acrylic block with the reference and auxiliary electrodes, to form the electrochemical (thin-layer) flow cell, while the contact pins are plugged into a standard IC socket, This design ensures autonomous electric contact with each electrode and allows fast dismantling for polishing or substitution, The performance of flow cells with MEACs was investigated utilizing the technique of reverse pulse amperometry without oxygen removal, A method was established for the determination of the copper concentration in sugar cane spirit, regulated by law for beverages, Samples from industrial producers and small-scale (alembic) brewers were compared, With a 24 MEAC, a detection limit of 30 mu g I-l of copper (4.7 x 10(-7) mol l(-1) of Cu-II for 100 mu l injections) was calculated, Routine operation was established at a frequency of 60-90 determinations per hour, Intercomparison with atomic absorption spectrometric determinations resulted in excellent agreement.
引用
收藏
页码:843 / 847
页数:5
相关论文
共 27 条
[1]  
*AGR MIN, 1974, BRAS LEIS DECR
[2]   DETERMINATION OF TRACE AMOUNTS OF ZINC, LEAD AND COPPER IN SUGAR-CANE SPIRITS BY ANODIC-STRIPPING VOLTAMMETRY [J].
BARBEIRA, PJS ;
MAZO, LH ;
STRADIOTTO, NR .
ANALYST, 1995, 120 (06) :1647-1650
[4]   FLOW-RATE INDEPENDENT AMPEROMETRIC CELL [J].
CAUDILL, WL ;
HOWELL, JO ;
WIGHTMAN, RM .
ANALYTICAL CHEMISTRY, 1982, 54 (14) :2532-2535
[5]  
FARIA JB, 1989, THESIS U SAO PAULO
[6]   GRAPHITE-POLY(TETRAFLUOROETHYLENE) ELECTRODES AS ELECTROCHEMICAL DETECTORS IN FLOWING SYSTEMS [J].
FERNANDEZ, C ;
REVIEJO, AJ ;
PINGARRON, JM .
ANALYTICA CHIMICA ACTA, 1995, 314 (1-2) :13-22
[7]   VOLTAMMETRIC INFORMATION FROM ARRAYS OF INDIVIDUALLY CONTROLLED ELECTRODES - THEIR POTENTIAL FOR INDUSTRIAL-PROCESS MEASUREMENTS [J].
FIELDEN, PR ;
MCCREEDY, T .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :111-121
[8]   AMPEROMETRIC ARRAYS IN FLOWING SOLUTION ANALYSIS [J].
FIELDEN, PR ;
MCCREEDY, T ;
RUCK, N ;
VAIREANU, DI .
ANALYST, 1994, 119 (05) :953-958
[9]  
LAFON R, 1964, COGNAC, P91
[10]  
MCGRATH MJ, 1995, ANAL LETT, V28, P685