Carbon-nanotube-enhanced direct electron-transfer reactivity of hemoglobin immobilized on polyurethane elastomer film

被引:51
作者
Liu, Songqin [1 ]
Lin, Baoping
Yang, Xiaodi
Zhang, Qianqian
机构
[1] SE Univ, Dept Chem & Chem Engn, Nanjing 210096, Peoples R China
[2] Nanjing Normal Univ, Coll Chem & Environm Sci, Nanjing 210097, Peoples R China
关键词
D O I
10.1021/jp065344b
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this study, we investigate the direct electron-transfer reactivity of immobilized hemoglobin (Hb) on a polyurethane elastomer (PUE) film for biosensor designs. The PUE film synthesized by an additional polymerization possesses good biocompatibility, uniformity, and conformability and is ready for protein immobilization. Electrochemical and spectroscopic measurements show that the presence of multiwalled carbon nanotubes (MWNTs) increased the protein-PUE interaction, varied polymer morphology, improved the permeability and the conductivity of the PUE film, and thus facilitated the direct electron transfer between the immobilized Hb and the conductivity surface through the conducting tunnels of MWNTs. The immobilized Hb maintains its bioactivities and displays an excellent electrochemical behavior with a formal potential of -(334 +/- 7) mV. The addition of NaNO2 leads to an increase of the electrocatalytic reduction current of nitrite at -0.7 V. This allows us to develop a nitrite sensor with a linear response range from 0.08 to 3.6 mM. The proposed method opens a way to develop biosensors by using nanostructured materials mixed with low electrical conductivity matrixes.
引用
收藏
页码:1182 / 1188
页数:7
相关论文
共 41 条
[1]   Direct electron transfer and bioelectrocatalysis of hemoglobin at a carbon nanotube electrode [J].
Cai, CX ;
Chen, J .
ANALYTICAL BIOCHEMISTRY, 2004, 325 (02) :285-292
[2]   Electropolymerization of hydroxybenzene and aminobenzene isomers on platinum electrodes to assemble interference-free electrochemical biosensors [J].
Carelli, I ;
Chiarotto, I ;
Curulli, A ;
Palleschi, G .
ELECTROCHIMICA ACTA, 1996, 41 (11-12) :1793-1800
[3]   Effect of the iridium oxide thin film on the electrochemical activity of platinum nanoparticles [J].
Chen, AC ;
La Russa, DJ ;
Miller, B .
LANGMUIR, 2004, 20 (22) :9695-9702
[4]   The characterization and bioelectrocatalytic properties of hemoglobin by direct electrochemistry of DDAB film modified electrodes [J].
Chen, SM ;
Tseng, CC .
ELECTROCHIMICA ACTA, 2004, 49 (12) :1903-1914
[5]   Electrochemically mediated electrodeposition/electropolymerization to yield a glucose microbiosensor with improved characteristics [J].
Chen, XH ;
Matsumoto, N ;
Hu, YB ;
Wilson, GS .
ANALYTICAL CHEMISTRY, 2002, 74 (02) :368-372
[6]   Direct electron transfer for hemoglobin in surfactant films cast on carbon electrodes [J].
Ciureanu, M ;
Goldstein, S ;
Mateescu, MA .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1998, 145 (02) :533-541
[7]   Stabilization of enzyme immunoassays for atrazine [J].
Dankwardt, A ;
Müller, J ;
Hock, B .
ANALYTICA CHIMICA ACTA, 1998, 362 (01) :35-45
[8]   USE OF POLYMER-FILMS IN AMPEROMETRIC BIOSENSORS [J].
EMR, SA ;
YACYNYCH, AM .
ELECTROANALYSIS, 1995, 7 (10) :913-923
[9]   Electron-transfer reactivity and enzymatic activity of hemoglobin in a SP sephadex membrane [J].
Fan, CH ;
Wang, HY ;
Sun, S ;
Zhu, DX ;
Wagner, G ;
Li, GX .
ANALYTICAL CHEMISTRY, 2001, 73 (13) :2850-2854
[10]   A conducting polymer nanojunction sensor for glucose detection [J].
Forzani, ES ;
Zhang, HQ ;
Nagahara, LA ;
Amlani, I ;
Tsui, R ;
Tao, NJ .
NANO LETTERS, 2004, 4 (09) :1785-1788