Three-Phase CH7 Inverter With a New Space Vector Modulation to Reduce Leakage Current for Transformerless Photovoltaic Systems

被引:113
作者
Guo, Xiaoqiang [1 ]
机构
[1] Yanshan Univ, Key Lab Power Elect Energy Conservat & Motor Driv, Dept Elect Engn, Qinhuangdao 066004, Peoples R China
基金
中国国家自然科学基金;
关键词
Current source H6 (CH6) inverter; current source H7 (CH7) inverter; current source inverter; leakage current; space vector modulation (SVM); GRID-CONNECTED INVERTER; CONVERTERS;
D O I
10.1109/JESTPE.2017.2662015
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Leakage current reduction is crucial for the transformerless photovoltaic inverters. The conventional threephase current source H6 inverter suffers from the large leakage current, which restricts its application to transformerless PV systems. In order to overcome the limitations, a new threephase current source H7 (CH7) inverter is proposed in this paper. Only one additional Insulated Gate Bipolar Transistor is needed, but the leakage current can be effectively suppressed with a new space vector modulation (SVM). Finally, the experimental tests are carried out on the proposed CH7 inverter, and the experimental results verify the effectiveness of the proposed topology and SVM method.
引用
收藏
页码:708 / 712
页数:5
相关论文
共 20 条
[1]   Three-Phase Boost-Type Grid-Connected Inverter [J].
Chen, Yang ;
Smedley, Keyue .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (05) :2301-2309
[2]   Dynamic Modeling and Performance Analysis of a Grid-Connected Current-Source Inverter-Based Photovoltaic System [J].
Dash, Prajna Paramita ;
Kazerani, Mehrdad .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2011, 2 (04) :443-450
[3]   A Novel CH5 Inverter for Single-Phase Transformerless Photovoltaic System Applications [J].
Guo, Xiaoqiang .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2017, 64 (10) :1197-1201
[4]   Flexible Power Regulation and Current-Limited Control of the Grid-Connected Inverter Under Unbalanced Grid Voltage Faults [J].
Guo, Xiaoqiang ;
Liu, Wenzhao ;
Lu, Zhigang .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (09) :7425-7432
[5]   Hardware-Based Cascaded Topology and Modulation Strategy With Leakage Current Reduction for Transformerless PV Systems [J].
Guo, Xiaoqiang ;
Jia, Xiaoyu .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (12) :7823-7832
[6]   Leakage Current Elimination of Four-Leg Inverter for Transformerless Three-Phase PV Systems [J].
Guo, Xiaoqiang ;
He, Ran ;
Jian, Jiamin ;
Lu, Zhigang ;
Sun, Xiaofeng ;
Guerrero, Josep M. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (03) :1841-1846
[7]   Common-Mode Voltage Mitigation for Back-to-Back Current-Source Converter With Optimal Space-Vector Modulation [J].
Guo, Xiaoqiang ;
Xu, David ;
Wu, Bin .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (01) :688-697
[8]   New inverter topology for ground current suppression in transformerless photovoltaic system application [J].
Guo, Xiaoqiang ;
Wang, Huaibao ;
Lu, Zhigang ;
Wang, Baocheng .
Journal of Modern Power Systems and Clean Energy, 2014, 2 (02) :191-194
[9]  
Guocheng San, 2012, Proceedings of the 2012 IEEE 7th International Power Electronics and Motion Control Conference (ECCE 2012), P163, DOI 10.1109/IPEMC.2012.6258884
[10]   Characterization of the insulation and leakage currents of PV generators: Relevance for human safety [J].
Hernandez, J. C. ;
Vidal, P. G. ;
Medina, A. .
RENEWABLE ENERGY, 2010, 35 (03) :593-601