Capillary liquid chromatographic-high-resolution mass spectrometric analysis of ribonucleotides

被引:28
作者
Cai, ZW
Song, FR
Yang, MS
机构
[1] Hong Kong Baptist Univ, Dept Chem, Kowloon, Hong Kong, Peoples R China
[2] Chinese Acad Sci, Changchun Inst Appl Chem, Changchun 130022, Jilin, Peoples R China
[3] Hong Kong Baptist Univ, Dept Biol, Kowloon, Hong Kong, Peoples R China
关键词
ion-pairing reagents; ribonucleotides; nucleotides; phosphates; dimethylhexylamine;
D O I
10.1016/S0021-9673(02)01155-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method of capillary HPLC-high-resolution MS was developed for the trace analysis of ATP, GTP, dATP and dGTP Dimethylhexylamine (DMHA) was used as ion-pairing agent for the HPLC retention and separation of the nucleotides and positive ion electrospray time-of-flight MS was used for the detection. The application of capillary HPLC allowed minimal usage of DMHA while providing excellent peak retention and resolution, which significantly reduced the ion suppression in electrospray ionization-MS analysis and thus increased the sensitivity. Adduct ions of nucleotides and DMHA were used as quantitative ions in order to achieve the best sensitivity. DMHA concentration at 5 mM in the aqueous mobile phase at pH 7 was found to be the optimal conditions for the C Is capillary column. The method was applied to determine ATP level in cultured C6 glioma cells that were treated with toxic concentrations of Zn. The results showed that the cellular ATP level decreased from 2.7 pmol/cell (<10% cell death) in average control cell samples to 0.36 pmol/cell as the concentration of Zn increased to 120 mg/l (>35% cell death) in culture medium. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:135 / 143
页数:9
相关论文
共 21 条
[1]   New procedure for the use of high-performance liquid chromatography electrospray ionization mass spectrometry for the analysis of nucleotides and oligonucleotides [J].
Apffel, A ;
Chakel, JA ;
Fischer, S ;
Lichtenwalter, K ;
Hancock, WS .
JOURNAL OF CHROMATOGRAPHY A, 1997, 777 (01) :3-21
[2]   Identification of adenine nucleotide-containing metabolites of bisphosphonate drugs using ion-pair liquid chromatography-electrospray mass spectrometry [J].
Auriola, S ;
Frith, J ;
Rogers, MJ ;
Koivuniemi, A ;
Mönkkönen, J .
JOURNAL OF CHROMATOGRAPHY B, 1997, 704 (1-2) :187-195
[3]   High sensitivity analysis of neutral underivatized oligosaccharides by nanoelectrospray mass spectrometry [J].
Bahr, U ;
Pfenninger, A ;
Karas, M ;
Stahl, B .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4530-4535
[4]   FAST ATOM BOMBARDMENT OF SOLIDS AS AN ION-SOURCE IN MASS-SPECTROMETRY [J].
BARBER, M ;
BORDOLI, RS ;
SEDGWICK, RD ;
TYLER, AN .
NATURE, 1981, 293 (5830) :270-275
[5]  
Brown PR, 1998, J MICROCOLUMN SEP, V10, P65, DOI 10.1002/(SICI)1520-667X(1998)10:1<65::AID-MCS9>3.0.CO
[6]  
2-X
[7]   Liquid chromatography mass spectrometry in nucleoside, nucleotide and modified nucleotide characterization [J].
Esmans, EL ;
Broes, D ;
Hoes, I ;
Lemière, F ;
Vanhoutte, K .
JOURNAL OF CHROMATOGRAPHY A, 1998, 794 (1-2) :109-127
[8]   Unique intracellular activation of the potent anti-human immunodeficiency virus agent 1592U89 [J].
Faletto, MB ;
Miller, WH ;
Garvey, EP ;
Clair, MHS ;
Daluge, SM ;
Good, SS .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1997, 41 (05) :1099-1107
[9]  
FREDERICKSON CJ, 1989, INT REV NEUROBIOL, V31, P145
[10]   Simultaneous determination of Ziagen and its phosphorylated metabolites by ion-pairing high-performance liquid chromatography-tandem mass spectrometry [J].
Fung, EN ;
Cai, ZW ;
Burnette, TC ;
Sinhababu, AK .
JOURNAL OF CHROMATOGRAPHY B, 2001, 754 (02) :285-295