Treatment of proximal humerus fractures with locking plates: A systematic review

被引:355
作者
Thanasas, Christos
Kontakis, George [2 ]
Angoules, Antonios
Limb, David
Giannoudis, Peter [1 ]
机构
[1] Leeds Gen Infirm, Acad Dept Trauma & Orthopaed, Leeds LS1 3EX, W Yorkshire, England
[2] Univ Crete, Khania, Greece
关键词
Proximal humerus; fractures; locking plate; systematic review; avascular necrosis; INTERNAL-FIXATION; 4-PART FRACTURES; OPEN REDUCTION; STABLE PLATE; 3-PART; PHILOS; OSTEOSYNTHESIS; EPIDEMIOLOGY; IMPLANT;
D O I
10.1016/j.jse.2009.06.004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Hypothesis: Locking plates with special configuration for the anatomic region of the proximal humerus have been introduced recently to address the difficulties of stabilizing proximal humeral fractures. The purpose of this Study was to carry Out a systematic review of the literature on the efficacy and early to medium term functional results of locking plates for stabilization of proximal humeral fractures. Methods: Using the PubMed database, a systematic review of the English and German literature was carried out in order to assess the efficacy and complications related to the use of these plates and the patients' functional outcome, using the key words "locking plates proximal humeral fractures," "angular stability plates proximal humeral fractures," "PHILOS plate," and "LPHP plate." Our criteria for eligibility were clinical studies with more than ten cases followed-up, adult patients, and adequate data provided at least in terms of implant related complications. Articles written in English and German language were included. Exclusion criteria were: studies dealing exclusively with 2-part fractures (since this category has a more favorable outcome); experimental studies; case reports; and, literature other than English or German. Each one of the articles was evaluated for quality of the study using the Structured Effectiveness Quality Evaluation Scale (SEQES). Results: Twelve studies including 791 patients met the inclusion criteria. Patients in these studies continued to improve up to one year, achieving a mean Constant score of 74.3. The incidence of the reported complications was: avascular necrosis 7.9%, screw cut-out 11.6% and re-operation rate 13.7%. Discussion: The high incidence of cut-out may be secondary to the rigidity of the implant in combination with medial inadequate support, in cases compromised by severe underlying osteoporotic bone. Definition of indications for the use of locking plates and attention on technical aspects of applying them would help optimization of the results. Level of evidence: Systematic Review. (C) 2009 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:837 / 844
页数:8
相关论文
共 34 条
[1]
Treatment of proximal humeral fractures with Polarus nail fixation [J].
Agel, J ;
Jones, CB ;
Sonzone, AG ;
Camuso, M ;
Henley, MB .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2004, 13 (02) :191-195
[2]
The epidemiology of peripheral fractures [J].
Baron, JA ;
Barrett, JA ;
Karagas, MR .
BONE, 1996, 18 (03) :S209-S213
[3]
Early failure of intramedullary nailing for proximal humeral fractures [J].
Bernard, J ;
Charalambides, C ;
Aderinto, J ;
Mok, D .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2000, 31 (10) :789-792
[4]
Internal fixation of proximal humeral fractures with a locking compression plate -: A retrospective evaluation of 72 patients followed for a minimum of 1 year [J].
Björkenheim, JM ;
Pajarinen, J ;
Savolainen, V .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (06) :741-745
[5]
Proximal humeral internal locking system (PHILOS) for the treatment of proximal humeral fractures [J].
Charalambous, C. P. ;
Siddique, I. ;
Valluripalli, K. ;
Kovacevic, M. ;
Panose, P. ;
Srinivasan, M. ;
Marynissen, H. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2007, 127 (03) :205-210
[6]
CHARLES M, 2006, INJURY, V37, P691
[7]
CONSTANT CR, 1987, CLIN ORTHOP RELAT R, P160
[8]
ESSER RD, 1994, CLIN ORTHOP RELAT R, P244
[9]
A new locking plate for unstable fractures of the proximal humerus [J].
Fankhauser, F ;
Boldin, C ;
Schippinger, G ;
Haunschmid, C ;
Szyszkowitz, R .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (430) :176-181
[10]
Proximal humeral fractures with angle-stable plate osteosynthesis -: Is everything better now? [J].
Frangen, T. M. ;
Dudda, M. ;
Martin, D. ;
Arens, S. ;
Greif, S. ;
Muhr, G. ;
Kaelicke, T. .
ZENTRALBLATT FUR CHIRURGIE, 2007, 132 (01) :60-69