Multiple-slice imaging of a tissue-equivalent phantom by use of time-resolved optical tomography

被引:37
作者
Schmidt, FEW
Hebden, JC
Hillman, EMC
Fry, ME
Schweiger, M
Dehghani, H
Delpy, DT
Arridge, SR
机构
[1] Royal Postgrad Med Sch, Dept Med Phys, London WC1E 6JA, England
[2] UCL, Dept Comp Sci, London WC1E 6BT, England
关键词
D O I
10.1364/AO.39.003380
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Following several years of development the construction of a multichannel time-resolved imaging device for medical optical tomography has been completed. Images are reconstructed from time-resolved measurements by use of a scheme that employs a finite-element diffusion-based forward model and an iterative reconstruction solver. Prior to testing on clinical subjects the fully automated instrument and the reconstruction software are evaluated with tissue-equivalent phantoms. We describe our first attempt to generate multiple-slice images of a phantom without uniform properties along the axial direction, while still using a computationally fast two-dimensional reconstruction algorithm. The image quality is improved by the employment of an approximate correction method that uses scaling factors derived from the ratios of finite-element forward simulations in two and three spatial dimensions. The 32-channel system was employed to generate maps of the internal scattering and the absorption properties at 14 different transverse planes across the phantom. The images clearly reveal the locations of small inhomogeneous regions embedded within the phantom. These results were obtained by use of purely temporal data and without resource to reference measurements. (C) 2000 Optical Society of America OCIS codes: 170.3010, 170.6920, 170.6960, 170.0110.
引用
收藏
页码:3380 / 3387
页数:8
相关论文
共 27 条
[1]   A gradient-based optimisation scheme for optical tomography [J].
Arridge, SR ;
Schweiger, M .
OPTICS EXPRESS, 1998, 2 (06) :213-226
[2]   Optical tomography in medical imaging [J].
Arridge, SR .
INVERSE PROBLEMS, 1999, 15 (02) :R41-R93
[3]  
ARRIDGE SR, 1993, P SOC PHOTO-OPT INS, V1888, P360, DOI 10.1117/12.154654
[4]  
ARRIDGE SR, IN PRESS INT J IMAGI
[5]   Phase measurement of light absorption and scatter in human tissue [J].
Chance, B ;
Cope, M ;
Gratton, E ;
Ramanujam, N ;
Tromberg, B .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (10) :3457-3481
[6]  
Chance B, 1999, P SPIE, V3597
[7]  
CHANCE B, 1997, PHILOS T R SOC LON B, V352, P649
[8]   Multichannel time-resolved optical tomographic imaging system [J].
Eda, H ;
Oda, I ;
Ito, Y ;
Wada, Y ;
Oikawa, Y ;
Tsunazawa, Y ;
Takada, M ;
Tsuchiya, Y ;
Yamashita, Y ;
Oda, M ;
Sassaroli, A ;
Yamada, Y ;
Tamura, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (09) :3595-3602
[9]   AN IMPROVED DESIGN FOR A STABLE AND REPRODUCIBLE PHANTOM MATERIAL FOR USE IN NEAR-INFRARED SPECTROSCOPY AND IMAGING [J].
FIRBANK, M ;
ODA, M ;
DELPY, DT .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (05) :955-961
[10]  
FUJIMOTO JG, 1998, OSA TRENDS OPTICS PH, V21