Noninvasive temperature estimation using sonographic digital images

被引:28
作者
Abolhassani, Mohammad D. [1 ]
Norouzy, Ahmad
Takavar, Abbas
Ghanaati, Hosein
机构
[1] Univ Tehran Med Sci, Sch Med, Med Phys & Biomed Engn Grp, Tehran, Iran
[2] Res Ctr Sci & Technol Med, Tehran, Iran
关键词
cross-correlation; speckle tracking; speed of sound; temperature monitoring; ultrasound;
D O I
10.7863/jum.2007.26.2.215
中图分类号
O42 [声学];
学科分类号
070206 [声学]; 082403 [水声工程];
摘要
Objective. The purpose of this study was to develop and evaluate a speckle-tracking method for tissue temperature estimation due to heating fields using digital sonographic images, Methods. The temperature change estimation method is based on the thermal dependence of the ultrasound speed and the thermal expansion of the medium. Local changes in the speed of sound due to changes in the temperature produce apparent displacement of the scatterers, and the expansion introduces physical displacement. In our study, a new technique has been introduced in which the axial physical displacements were obtained from digital sonographic images. The axial speckle pattern displacement was determined with a cross-correlation algorithm. The displacement data were then used for computing the temperature changes. To monitor the temperature in real time, the computational time was decreased by restricting the search region in the cross-correlation algorithm and carrying out the cross-correlation function in the frequency domain via a fast Fourier transform algorithm. Results. Experiments were performed on tissue-mimicking phantoms. The imaging probe was a commercial linear array working at 10 MHz. In addition, the temperature changes during heating were measured invasively by negative temperature coefficient thermistors. There was good agreement between ultrasonic temperature estimations and invasive temperature measurements. Conclusions. The proposed method verifies the capability of the speckle-tracking algorithm for determining both the magnitude and direction of displacement. The average error was 0.2 degrees C; the maximum error was 0.53 degrees C; and the SD was 0.19 degrees C. Therefore, the proposed algorithm is capable of extracting the temperature information from sonographic digital images.
引用
收藏
页码:215 / 222
页数:8
相关论文
共 24 条
[1]
ADAM D, 2004, MED C MED BIOL ENG J
[2]
Non-invasive estimation of hyperthermia temperatures with ultrasound [J].
Arthur, RM ;
Straube, WL ;
Trobaugh, JW ;
Moros, EG .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2005, 21 (06) :589-600
[3]
BAMBER J C, 1979, Ultrasound in Medicine and Biology, V5, P149, DOI 10.1016/0301-5629(79)90083-8
[4]
Closed-loop feedback control of phased-array microwave heating using thermal measurements from magnetic resonance imaging [J].
Behnia, B ;
Suthar, M ;
Webb, AG .
CONCEPTS IN MAGNETIC RESONANCE, 2002, 15 (01) :101-110
[5]
Speckle tracking for multi-dimensional flow estimation [J].
Bohs, LN ;
Geiman, BJ ;
Anderson, ME ;
Gebhart, SC ;
Trahey, GE .
ULTRASONICS, 2000, 38 (1-8) :369-375
[6]
Ultrasound imaging of thermal therapy in in vitro liver [J].
Gertner, MR ;
Worthington, AE ;
Wilson, BC ;
Sherar, MD .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (07) :1023-1032
[7]
Goldberg S N, 2001, Eur J Ultrasound, V13, P129, DOI 10.1016/S0929-8266(01)00126-4
[8]
HANEY MJ, 1986, TISSUE CHARACTERIZAT, P15
[9]
CURRENT TIME-DOMAIN METHODS FOR ASSESSING TISSUE MOTION BY ANALYSIS FROM REFLECTED ULTRASOUND ECHOES - A REVIEW [J].
HEIN, IA ;
OBRIEN, WD .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1993, 40 (02) :84-102
[10]
In vivo MRI thermometry using a phase-sensitive sequence:: Preliminary experience during MRI-guided laser-induced interstitial thermotherapy of brain tumors [J].
Kahn, T ;
Harth, T ;
Kiwit, JCW ;
Schwarzmaier, HJ ;
Wald, C ;
Mödder, U .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :160-164