Analysis of MPPT characteristics in photovoltaic power system

被引:39
作者
Kawamura, T
Harada, K
Ishihara, Y
Todaka, T
Oshiro, T
Nakamura, H
Imataki, M
机构
[1] DOSHISHA UNIV,DEPT ELECT ENGN,KYOTO 61003,JAPAN
[2] JAPAN QUAL ASSURANCE ORG,SOLAR TECHNO CTR,HAMAMATSU,SHIZUOKA 433,JAPAN
关键词
photovoltaic power system; Maximum Power Point Tracking;
D O I
10.1016/S0927-0248(97)00036-6
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper describes characteristics evaluation of the power conditioner which has the function of Maximum Power Point Tracking (MPPT) by ''mountain climbing method'' through computer simulations. The generated power on the constant voltage control is compared to the one on MPPT with the load matching correction factor (Kpm). In this simulation, the following parameters are chosen, the rate of the voltage Delta V on changing the operating point and of the voltage Delta V-c, on checking the maximum point. As a result, the influence of these parameters on Kpm is showed and it is made clear that we should decide the MPPT parameters with care.
引用
收藏
页码:155 / 165
页数:11
相关论文
empty