Evaluation of OC/EC speciation by thermal manganese dioxide oxidation and the IMPROVE method

被引:94
作者
Fung, K
Chow, JC
Watson, JG
机构
[1] AtmAA Inc, Calabasas, CA 91302 USA
[2] Univ & Community Coll Syst Nevada, Desert Res Inst, Reno, NV 89512 USA
来源
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION | 2002年 / 52卷 / 11期
关键词
D O I
10.1080/10473289.2002.10470867
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ambient particulate samples are routinely analyzed for organic and elemental carbon (OC/EC) using either thermal manganese dioxide oxidation (TMO) or thermal volatilization-pyrolysis correction methods, such as the Interagency Monitoring of PROtected Visual Environments (IMPROVE) method with correction by reflectance, or a variation of the National Institute of Occupational Safety and Health (NIOSH) Method 5040 using thermal optical transmittance (TOT). With TMO, EC is modeled after the oxidation properties of submicron graphite and needle coke by MnO2, and is the fraction of total carbon (TC) that is not oxidized at >525 degreesC. In thermal volatilization methods, EC is the fraction of TC that accounts for the light extinction properties of the sample at the start of analysis. Chow et al. (2001) compared IMPROVE and NIOSH methods implemented on the same instrument using 60 samples of various types and found that NIOSH EC was lower than IMPROVE. This study compares total, organic, and elemental carbon measurements from the TMO and IMPROVE thermal optical reflectance (TOR) methods using a sample set consisting of 60 IMPROVE nonurban, 16 Korean urban, 10 Hong Kong urban, and 14 synthetic carbon black samples.
引用
收藏
页码:1333 / 1341
页数:9
相关论文
共 70 条