Detection of single ion channel activity on a chip using tethered bilayer membranes

被引:63
作者
Andersson, Martin
Keizer, Henk M.
Zhu, Chenyu
Fine, Daniel
Dodabalapur, Ananth
Duran, Randolph S. [1 ]
机构
[1] Univ Florida, Dept Chem, Gainesville, FL 32611 USA
[2] Univ Texas, Microelect Res Ctr, Austin, TX 78712 USA
关键词
D O I
10.1021/la063503c
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Membrane-bound ion channels are promising biological receptors since they allow for the stochastic detection of analytes at high sensitivity. For stochastic sensing, it is necessary to measure the ion currents associated with single ion channel opening and closing events. However, this calls for stability, high reproducibility, and long lifetimes. A critical issue to overcome is the low stability of the ion channel environment, that is, the bilayer membrane. A promising technique to surmount this is to connect the lower part of the membrane to a surface forming a tethered bilayer membrane. By reconstituting the synthetic ion channel, gramicidin A, into a tethered bilayer as part of a microchip design, we have been able to record the activity of single ion channels. The observed activity was compared with that obtained by a conventional electrophysiology method, tip dipping, to confirm its authenticity. These findings allow for the construction of stable biosensors based on ion channels and provide a novel technique for the characterization of ion channel activity.
引用
收藏
页码:2924 / 2927
页数:4
相关论文
共 14 条
[1]   Stochastic sensors inspired by biology [J].
Bayley, H ;
Cremer, PS .
NATURE, 2001, 413 (6852) :226-230
[2]   A biosensor that uses ion-channel switches [J].
Cornell, BA ;
BraachMaksvytis, VLB ;
King, LG ;
Osman, PDJ ;
Raguse, B ;
Wieczorek, L ;
Pace, RJ .
NATURE, 1997, 387 (6633) :580-583
[3]   PHOSPHOLIPID-BILAYERS MADE FROM MONOLAYERS ON PATCH-CLAMP PIPETTES [J].
CORONADO, R ;
LATORRE, R .
BIOPHYSICAL JOURNAL, 1983, 43 (02) :231-236
[4]   Stochastic sensing of organic analytes by a pore-forming protein containing a molecular adapter [J].
Gu, LQ ;
Braha, O ;
Conlan, S ;
Cheley, S ;
Bayley, H .
NATURE, 1999, 398 (6729) :686-690
[5]  
HALL JE, 1976, BIOPHYS J, V15, P99
[6]  
Knoll W, 2000, J Biotechnol, V74, P137, DOI 10.1016/S1389-0352(00)00012-X
[7]  
Koeppe RE, 1996, ANNU REV BIOPH BIOM, V25, P231
[8]   Tethered bilayer membranes containing ionic reservoirs: Selectivity and conductance [J].
Krishna, G ;
Schulte, J ;
Cornell, BA ;
Pace, RJ ;
Osman, PD .
LANGMUIR, 2003, 19 (06) :2294-2305
[9]   Tethered lipid Bilayers on ultraflat gold surfaces [J].
Naumann, R ;
Schiller, SM ;
Giess, F ;
Grohe, B ;
Hartman, KB ;
Kärcher, I ;
Köper, I ;
Lübben, J ;
Vasilev, K ;
Knoll, W .
LANGMUIR, 2003, 19 (13) :5435-5443
[10]   Membrane surface-charge titration probed by gramicidin A channel conductance [J].
Rostovtseva, TK ;
Aguilella, VM ;
Vodyanoy, I ;
Bezrukov, SM ;
Parsegian, VA .
BIOPHYSICAL JOURNAL, 1998, 75 (04) :1783-1792