Performance reassessment of a real-time seizure-detection algorithm on long ECoG series

被引:103
作者
Osorio, I
Frei, MG
Giftakis, J
Peters, T
Ingram, J
Turnbull, M
Herzog, M
Rise, MT
Schaffner, S
Wennberg, RA
Walczak, TS
Risinger, MW
Ajmone-Marsan, C
机构
[1] Univ Kansas, Med Ctr, Comprehens Epilepsy Ctr, Kansas City, KS 66160 USA
[2] LLC, Flint Hills Sci, Lawrence, KS USA
[3] Medtronic Inc, Toronto, ON, Canada
[4] Toronto Western Res Inst, Div Clin Studies Resource Ctr, Toronto, ON, Canada
[5] MINCEP, Epilepsy Care, Minneapolis, MN USA
[6] Stanford Univ, Dept Neurol & Neurol Sci, Stanford, CA 94305 USA
[7] Univ Miami, Dept Neurol, Miami, FL 33152 USA
关键词
real-time; seizure; detection; algorithm; warning;
D O I
10.1046/j.1528-1157.2002.11102.x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose: Automated seizure detection and blockage requires highly sensitive and specific algorithms. This study reassessed the performance of an algorithm by using a more extensive database than that of a previous study and its suitability for safety/efficacy closed-loop studies to block seizures in humans. Methods: Up to eight electrocorticography (EcoG) channels from 15 subjects were analyzed off-line. Visual and computerized analyses of the data were performed by different (blinded) investigators. Independent visual analysis also was performed for clinical seizures and for detections identified only by the algorithm. The following were computed: FP rate, number of FNs, latency to automated detection, warning rate for clinical onset and warning times, seizure duration/intensity, and interrater agreement. Adaptations to improve performance were performed when indicated. Results: Fourteen subjects met inclusion criteria. Generic algorithm "relative sensitivity" for clinical seizures was 100%; two undetected subclinical seizures and two unclassified seizures were captured after adaptation. FPs/day were zero in seven and fewer than one in an additional three subjects. Adaptations for four subjects with greater than 1 FP/day (7.7-66.6/day) reduced the rate to 0 in one subject and to fewer than five FP/day (1.7-4.2/day) in the remainder. Generic latency to automated detection was <5 s in eight of 13 subjects, and in 12 of 13 after adaptation. Detections provided warning of clinical onset in three of four subjects in whom it always followed electrographic onset, and in four of four after adaptation. Interrater agreement was low for FPs and EDs. Conclusions: The generic algorithm demonstrated high sensitivity, specificity, and speed, characteristics further enhanced by adaptation. This algorithm is well suited for seizure detection/warning and use in safety/efficacy closed-loop therapy studies.
引用
收藏
页码:1522 / 1535
页数:14
相关论文
共 14 条
[1]   A COEFFICIENT OF AGREEMENT FOR NOMINAL SCALES [J].
COHEN, J .
EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1960, 20 (01) :37-46
[2]  
Daubechies I., 1993, Ten Lectures of Wavelets, V28, P350
[3]  
FISHER RS, 1996, AES NEWS FAL, P5
[4]   AUTOMATIC RECOGNITION AND QUANTIFICATION OF INTERICTAL EPILEPTIC ACTIVITY IN HUMAN SCALP EEG [J].
GOTMAN, J ;
GLOOR, P .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1976, 41 (05) :513-529
[5]   SIGNIFICANCE OF FOCAL AND LATERALIZED BETA ACTIVITY IN THE EEG [J].
HOOSHMAND, H ;
MORGANROTH, R ;
CORREDOR, C .
CLINICAL ELECTROENCEPHALOGRAPHY, 1980, 11 (03) :140-144
[6]   Brief bursts of pulse stimulation terminate afterdischarges caused by cortical stimulation [J].
Lesser, RP ;
Kim, SH ;
Beyderman, L ;
Miglioretti, DL ;
Webber, WRS ;
Bare, M ;
Cysyk, B ;
Krauss, G ;
Gordon, B .
NEUROLOGY, 1999, 53 (09) :2073-2081
[7]   Hippocampal sleep spindles revisited: physiologic or epileptic activity? [J].
Malow, BA ;
Carney, PR ;
Kushwaha, R ;
Bowes, RJ .
CLINICAL NEUROPHYSIOLOGY, 1999, 110 (04) :687-693
[8]   SLEEP SPINDLES IN THE HUMAN HIPPOCAMPUS - NORMAL OR EPILEPTIC ACTIVITY [J].
MONTPLAISIR, J ;
LEDUC, L ;
LAVERDIERE, M ;
WALSH, J ;
SAINTHILAIRE, JM .
SLEEP, 1981, 4 (04) :423-428
[9]   PAROXYSMAL-BETA ACTIVITY IN PEDIATRIC ELECTROENCEPHALOGRAM [J].
NEALIS, JGT ;
DUFFY, FH .
ANNALS OF NEUROLOGY, 1978, 4 (02) :112-116
[10]   Real-time automated detection and quantitative analysis of seizures and short-term prediction of clinical onset [J].
Osorio, I ;
Frei, MG ;
Wilkinson, SB .
EPILEPSIA, 1998, 39 (06) :615-627