Two dimensional reversed-phase-reversed-phase separations -: Isomeric separations incorporating C18 and carbon clad zirconia stationary phases

被引:71
作者
Gray, M
Dennis, GR
Wormell, P
Shalliker, RA [1 ]
Slonecker, P
机构
[1] Univ Western Sydney, Ctr Biostruct & Biomol Res, Sydney, NSW 1797, Australia
[2] Cognis Corp, Tech Ctr, Cincinnati, OH 45323 USA
关键词
stationary phases; LC; two-dimensional reversed-phase chromatography; carbon clad zirconia; silica; octadecyl bonded;
D O I
10.1016/S0021-9673(02)01221-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Informational theory and a geometric approach to factor analysis were employed to evaluate the degree of orthogonality of a two-dimensional reversed-phase-reversed-phase chromatographic system. The system incorporated a C-18 column as one dimension and a carbon clad zirconia column as the second dimension. In order to study the resolving power of this system, the separation of a sample matrix containing an artificial mix of 32 isomers (structural and diastereoisomers) was evaluated. Using this system, between 25 and 28 of the 32 isomers could be separated, depending on the mobile phase combinations with resolution that could not possibly be achieved in a single one dimensional separation. The results from this study indicate that in order to fully evaluate the resolving power of a 2D system multiple methods of analysis are most appropriate. This becomes increasingly important when the sample contains components that are very closely related and the retention of solutes is clustered in one quadrant of the 2D space. Ultimately, the usefulness of the 2D separation is determined by the goals of analyst. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:285 / 297
页数:13
相关论文
共 41 条
[1]  
Bertsch W, 2000, HRC-J HIGH RES CHROM, V23, P167
[2]  
BERTSCH W, 1990, MULTIDIMENSIONAL CHR
[3]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY CAPILLARY ZONE ELECTROPHORESIS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :978-984
[4]   STATISTICAL-METHOD FOR ESTIMATION OF NUMBER OF COMPONENTS FROM SINGLE COMPLEX CHROMATOGRAMS - THEORY, COMPUTER-BASED TESTING, AND ANALYSIS OF ERRORS [J].
DAVIS, JM ;
GIDDINGS, JC .
ANALYTICAL CHEMISTRY, 1985, 57 (12) :2168-2177
[5]  
De Geus H.-J., 1996, TRENDS ANAL CHEM, V15, P398
[6]   THE MECHANISM OF SOLUTE RETENTION IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
DILL, KA .
JOURNAL OF PHYSICAL CHEMISTRY, 1987, 91 (07) :1980-1988
[7]   THE MOLECULAR MECHANISM OF RETENTION IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
DORSEY, JG ;
DILL, KA .
CHEMICAL REVIEWS, 1989, 89 (02) :331-346
[8]  
Frysinger GS, 1999, HRC-J HIGH RES CHROM, V22, P195
[9]   SAMPLE DIMENSIONALITY - A PREDICTOR OF ORDER-DISORDER IN COMPONENT PEAK DISTRIBUTION IN MULTIDIMENSIONAL SEPARATION [J].
GIDDINGS, JC .
JOURNAL OF CHROMATOGRAPHY A, 1995, 703 (1-2) :3-15
[10]   TWO-DIMENSIONAL SEPARATIONS - CONCEPT AND PROMISE [J].
GIDDINGS, JC .
ANALYTICAL CHEMISTRY, 1984, 56 (12) :1258-&