Comparative analysis of tea catechins and theaflavins by highperformance liquid chromatography and capillary electrophoresis

被引:164
作者
Lee, BL [1 ]
Ong, CN [1 ]
机构
[1] Natl Univ Singapore, Dept Community Occupat & Family Med, Singapore 117597, Singapore
基金
英国医学研究理事会;
关键词
tea; food analysis; catechins; theaflavins; flavonoids; polyphenols;
D O I
10.1016/S0021-9673(00)00215-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes the simultaneous determination of catechins and theaflavins in green and black teas, using reversed-phase high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE). The tea polyphenols analyzed including (+)-catechin gallate, (-)-epicatechin, epicatechin-3-gallate, epigallocatechin, epigallocatechin-3-gallate theaflavin, theaflavin-3-monogallate, theaflavin-3'-monogallate and theaflavin-3,3'-gallate. These polyphenols together with six other tea ingredients such as caffeine, adenine, theophylline, quercetin, gallic acid and caffeic acid were separated within 27 min by HPLC and in less than 10 min by CE. The optimal analytical conditions of both chromatographic methods were investigated for the convenience and reliability for routine analysis. Both HPLC and CE were found to be reliable and compatible. The reproducibility of the within-day assay using both methods was generally >90%. The day-to-day variation of retention time was <5% for HPLC, while the variation of migration time for CE was <2%. The analysis time of CE was three-times faster, however it is five-times less sensitive than HPLC, which has detection limits of 0.05 mu g/ml and 0.5 mu g/ml for catechins and theaflavins, respectively. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:439 / 447
页数:9
相关论文
共 28 条
  • [1] Determination of anti-carcinogenic polyphenols present in green tea using capillary electrophoresis coupled to a flow injection system
    Arce, L
    Ríos, A
    Valcárcel, M
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 827 (01) : 113 - 120
  • [2] Barroso MB, 1999, HRC-J HIGH RES CHROM, V22, P225, DOI 10.1002/(SICI)1521-4168(19990401)22:4&lt
  • [3] 225::AID-JHRC225&gt
  • [4] 3.0.CO
  • [5] 2-V
  • [6] Chen CW, 1998, J FOOD DRUG ANAL, V6, P713
  • [7] Selection of column and gradient elution system for the separation of catechins in green tea using high-performance liquid chromatography
    Dalluge, JJ
    Nelson, BC
    Thomas, JB
    Sander, LC
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 793 (02) : 265 - 274
  • [8] Dalluge JJ, 1997, RAPID COMMUN MASS SP, V11, P1753, DOI 10.1002/(SICI)1097-0231(19971030)11:16<1753::AID-RCM92>3.0.CO
  • [9] 2-G
  • [10] CHROMATOGRAPHY OF TEA CONSTITUENTS
    FINGER, A
    KUHR, S
    ENGELHARDT, UH
    [J]. JOURNAL OF CHROMATOGRAPHY, 1992, 624 (1-2): : 293 - 315