Supercritical CO2 assisted liquid extraction of nitroaromatic and polycyclic aromatic compounds in soil

被引:24
作者
Deuster, R [1 ]
Lubahn, N [1 ]
Friedrich, C [1 ]
Kleibohmer, W [1 ]
机构
[1] INST CHEMO & BIOSENSOR,D-48149 MUNSTER,GERMANY
关键词
soil analysis; nitroaromatic compounds; polycyclic aromatic compounds; carbon dioxide;
D O I
10.1016/S0021-9673(97)00459-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work we present a supercritical fluid extraction method based on the technique of direct modifier addition, This supercritical CO2 assisted liquid extraction method proves to be superior to conventional liquid extraction methods such as sonication or Soxhlet extraction. Furthermore we investigated the influences of polar additives in the modifier on extraction behaviour. Analytes of interest were polycyclic aromatic hydrocarbons and for the first time the extraction of nitroaromatic compounds and other explosive residues was attempted in real-world soil samples, Due to the use of an especially developed solid-liquid trapping system we were able to integrate a clean-up step (ICUS). Additionally, this trapping system allows quantitative recovery of even volatile nitroaromatics. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:227 / 238
页数:12
相关论文
共 17 条
[1]   SUPERCRITICAL-FLUID EXTRACTION IN ENVIRONMENTAL-ANALYSIS [J].
BOWADT, S ;
HAWTHORNE, SB .
JOURNAL OF CHROMATOGRAPHY A, 1995, 703 (1-2) :549-571
[2]   EXTRACTION RATES OF SPIKED VERSUS NATIVE PAHS FROM HETEROGENEOUS ENVIRONMENTAL-SAMPLES USING SUPERCRITICAL-FLUID EXTRACTION AND SONICATION IN METHYLENE-CHLORIDE [J].
BURFORD, MD ;
HAWTHORNE, SB ;
MILLER, DJ .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :1497-1505
[3]  
DEUSTER R, 1996, THESIS U MUNSTER
[4]  
*DTSCH I NORM, 1993, NORM WASS 21
[5]   SAMPLE PREPARATION BY SUPERCRITICAL FLUID EXTRACTION IN ENVIRONMENTAL FOOD AND POLYMER ANALYSIS [J].
ENGELHARDT, H ;
ZAPP, J ;
KOLLA, P .
CHROMATOGRAPHIA, 1991, 32 (11-12) :527-537
[6]   MATRIX INDEPENDENT SUPERCRITICAL-FLUID EXTRACTION OF POLYCYCLIC AROMATIC-HYDROCARBONS BY EMPLOYING BINARY MODIFIERS [J].
FRIEDRICH, C ;
CAMMANN, K ;
KLEIBOHMER, W .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 352 (7-8) :730-734
[7]   COMPARISON OF SUPERCRITICAL CHCLF2, N2O, AND CO2 FOR THE EXTRACTION OF POLYCHLORINATED-BIPHENYLS AND POLYCYCLIC AROMATIC-HYDROCARBONS [J].
HAWTHORNE, SB ;
LANGENFELD, JJ ;
MILLER, DJ ;
BURFORD, MD .
ANALYTICAL CHEMISTRY, 1992, 64 (14) :1614-1622
[8]   STUDIES ON TRAPPING EFFICIENCIES OF VARIOUS COLLECTION DEVICES FOR OFF-LINE SUPERCRITICAL-FLUID EXTRACTION [J].
HUSERS, N ;
KLEIBOHMER, W .
JOURNAL OF CHROMATOGRAPHY A, 1995, 697 (1-2) :107-114
[9]   ROLE OF MODIFIERS FOR ANALYTICAL-SCALE SUPERCRITICAL-FLUID EXTRACTION OF ENVIRONMENTAL-SAMPLES [J].
LANGENFELD, JJ ;
HAWTHORNE, SB ;
MILLER, DJ ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1994, 66 (06) :909-916
[10]  
LEWIS U, 1996, 21 INT S CHROM STUTT