Selective use of diagnostic tests in patients with syncope of unknown cause

被引:37
作者
Garcia-Civera, R [1 ]
Ruiz-Granell, R [1 ]
Morell-Cabedo, S [1 ]
Sanjuan-Mañez, R [1 ]
Perez-Alcala, F [1 ]
Plancha, E [1 ]
Navarro, A [1 ]
Botella, S [1 ]
Llacer, A [1 ]
机构
[1] Univ Valencia, Hosp Clin, Dept Cardiol, Valencia, Spain
关键词
D O I
10.1016/S0735-1097(02)02929-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES We sought to prospectively assess the diagnostic yielding of a protocol in which electrophysiologic studies (EPS), tilt-table tests (TTTs), and loop recorder implantation are selectively used. BACKGROUND The optimal strategy in the diagnosis of patients with syncope of unknown cause has not been defined. METHODS A total of 184 consecutive patients with syncope of unknown cause were classified into two groups. Group A consisted of 72 patients fulfilling any of the following criteria: 1) presence of structural heart disease or family history of sudden death; 2) abnormal electrocardiogram; 3) significant non-symptomatic arrhythmia on Holter monitoring; and 4) paroxysmal palpitations immediately before or after syncope. These patients initially underwent an EPS and, if this study was negative, TTT. In the remaining 112 patients (group B), TTT was performed RESULTS The EPS was positive in 32 patients (44%) in group A. The TTT was positive in 80 patients (71%) in group B. An additional patient had carotid sinus hypersensitivity. In patients of group A with a negative EPS, the TTT was positive in 23 (57%). A loop recorder was implanted in 15 patients from group A with negative conventional testing, and diagnostic activation was obtained in seven patients. Overall, a positive diagnosis was achieved in 143 patients (78%). CONCLUSIONS In patients with syncope of unknown cause, selective use of EPS or TTT leads to a positive diagnosis in >70% of the cases. An implantable loop recorder can be useful in non-diagnosed cases. (C) 2003 by the American College of Cardiology Foundation.
引用
收藏
页码:787 / 790
页数:4
相关论文
共 18 条
[1]   Diagnostic value of history in patients with syncope with or without heart disease [J].
Alboni, P ;
Brignole, M ;
Menozzi, C ;
Raviele, A ;
Del Rosso, A ;
Dinelli, M ;
Solano, A ;
Bottoni, N .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (07) :1921-1928
[2]   'The Italian Protocol': a simplified head-up tilt testing potentiated with oral nitroglycerin to assess patients with unexplained syncope [J].
Bartoletti, A ;
Alboni, P ;
Ammirati, F ;
Brignole, M ;
Del Rosso, A ;
Manzillo, GF ;
Menozzi, C ;
Raviele, A ;
Sutton, R .
EUROPACE, 2000, 2 (04) :339-342
[3]   Tilt table testing for assessing syncope [J].
Benditt, DG ;
Ferguson, DW ;
Grubb, BP ;
Kapoor, WN ;
Kugler, J ;
Lerman, BB ;
Maloney, JD ;
Raviele, A ;
Ross, B ;
Sutton, R ;
Wolk, MJ ;
Wood, DL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (01) :263-275
[4]   Guidelines on management (diagnosis and treatment) of syncope [J].
Brignole, M ;
Alboni, P ;
Benditt, D ;
Bergfeldt, L ;
Blanc, JJ ;
Thomsen, PEB ;
van Dijk, JG ;
Fitzpatrick, A ;
Hohnloser, S ;
Janousek, J ;
Kapoor, W ;
Kenny, RA ;
Kulakowski, P ;
Moya, A ;
Raviele, A ;
Sutton, R ;
Theodorakis, G ;
Wieling, W .
EUROPEAN HEART JOURNAL, 2001, 22 (15) :1256-1306
[5]   Mechanism of syncope in patients with bundle branch block and negative electrophysiological test [J].
Brignole, M ;
Menozzi, C ;
Moya, A ;
Garcia-Civera, R ;
Mont, L ;
Alvarez, M ;
Errazquin, F ;
Beiras, J ;
Bottoni, N ;
Donateo, P .
CIRCULATION, 2001, 104 (17) :2045-2050
[6]   Implantable loop recorder: towards a gold standard for the diagnosis of syncope? [J].
Brignole, M ;
Menozzi, C ;
Moya, A ;
Garcia-Civera, R .
HEART, 2001, 85 (06) :610-612
[7]  
Brignole M, 1997, CIRCULATION, V96, P3921
[8]   Diagnostic accuracy of a protocol in the evaluation of unexplained syncope [J].
Civera, RG ;
Máñez, RS ;
Granell, RR ;
Cabedo, SM ;
Azpíroz, JCP ;
Ros, VR ;
Solana, SB .
REVISTA ESPANOLA DE CARDIOLOGIA, 2001, 54 (04) :425-430
[9]   Can adenosine 5'-triphosphate be used to select treatment in severe vasovagal syndrome? [J].
Flammang, D ;
Church, T ;
Waynberger, M ;
Chassing, A ;
Antiel, M .
CIRCULATION, 1997, 96 (04) :1201-1208
[10]   VALUE AND LIMITATIONS OF CLINICAL ELECTROPHYSIOLOGIC STUDY IN ASSESSMENT OF PATIENTS WITH UNEXPLAINED SYNCOPE [J].
GULAMHUSEIN, S ;
NACCARELLI, GV ;
KO, PT ;
PRYSTOWSKY, EN ;
ZIPES, DP ;
BARNETT, HJM ;
HEGER, JJ ;
KLEIN, GJ .
AMERICAN JOURNAL OF MEDICINE, 1982, 73 (05) :700-705