The ''RAPID'' high rate large area X-ray detector system

被引:45
作者
Lewis, RA
Helsby, WI
Jones, AO
Hall, CJ
Parker, B
Sheldon, J
Clifford, P
Hillen, M
Sumner, I
Fore, NS
Jones, RWM
Roberts, KM
机构
[1] ROBINSON INSTRUMENTS,RUNCORN,CHESHIRE,ENGLAND
[2] UNIV LONDON IMPERIAL COLL SCI & TECHNOL,LONDON,ENGLAND
[3] LECROY CORP,CHESTNUT RIDGE,NY 10977
关键词
D O I
10.1016/S0168-9002(97)00211-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The multiwire proportional counter (MWPC) is a well-established device for capturing X-ray images from synchrotron sources and is particularly well suited to dynamic experiments. Its advantages include, almost zero noise, high dynamic range limited only by the electronic memory depth, large area and time resolutions of microseconds. It does however have some limitations, notably in global and local count rate performance. The RAPID two-dimensional detector system delivers a more than twentyfold increase in throughput over present systems. It comprises a ''wire MicroGap'' detector, which has much higher count rate performance than coventional MWPCs and a sophisticated multi-channel data acquisition system. The system has a global count rate capability of greater than 2 x 10(7) photons s(-1) with a maximum local count rate of similar to 10(6) photons mm(-2) s(-1). A spatial resolution of similar to 200 mu m, over an active area of 12.8 x 12.8 cm, has been achieved which compares well with exiting read-out systems. Each electrode of the detector is instrumented with a preamplifier and ADC and the position of the event is determined independently in X and Y by centroiding the induced charge distribution. The X and Y coordinates are correlated using a unique time stamp. This paper described the design and performance of the detector and read-out system and presents some recent beamline results.
引用
收藏
页码:32 / 41
页数:10
相关论文
共 8 条
[1]   OPTIMUM GEOMETRY FOR STRIP CATHODES OR GRIDS IN MWPC FOR AVALANCHE LOCALIZATION ALONG THE ANODE WIRES [J].
GATTI, E ;
LONGONI, A ;
OKUNO, H ;
SEMENZA, P .
NUCLEAR INSTRUMENTS & METHODS, 1979, 163 (01) :83-92
[2]   DEVELOPMENT OF DATA-ACQUISITION FOR DELAY-LINE READOUT GAS PROPORTIONAL CHAMBERS [J].
HELSBY, WI ;
BERRY, A ;
HALL, CJ ;
JONES, AO ;
LEWIS, RA ;
PARKER, B ;
SUMNER, I .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3) :329-333
[3]   DESIGN CONSIDERATIONS FOR PREAMPLIFIERS TO BE USED ON FAST MULTIWIRE GAS PROPORTIONAL COUNTER READOUT SYSTEMS [J].
JONES, AO ;
FORE, NS ;
CLIFFORD, P ;
HALL, C ;
HELSBY, WI ;
LEWIS, RA ;
PARKER, B ;
SHELDON, J ;
SUMNER, I .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3) :256-260
[4]   The daresbury fast multi-wire linear X-ray detector system [J].
Lewis, RA ;
Hall, CJ ;
Parker, B ;
Jones, A ;
Helsby, W ;
Sheldon, JW ;
Clifford, P ;
Hillon, M ;
Fore, N .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3) :42-46
[5]   HIGH COUNTING RATE GASEOUS X-RAY-DETECTORS FOR SYNCHROTRON RADIATION APPLICATIONS [J].
LEWIS, RA ;
FORE, NS ;
HELSBY, W ;
HALL, C ;
JONES, A ;
PARKER, B ;
SUMNER, I ;
WORGAN, JS ;
BUDTZJORGENSEN, C .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :642-647
[6]   CATHODE CHARGE-DISTRIBUTIONS IN MULTIWIRE CHAMBERS .2. APPROXIMATE AND EMPIRICAL FORMULAS [J].
MATHIESON, E ;
GORDON, JS .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 227 (02) :277-282
[7]   Large area, 2-D, high-pressure MWPC for-wide angle X-ray diffraction [J].
OrtunoPrados, F ;
Hall, C ;
Helsby, W ;
Jones, A ;
Lewis, R ;
Parker, B ;
Sheldon, J ;
Bazzano, A ;
Ubertini, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3) :47-50
[8]  
STEPHENSON R, 1978, RL78043 RUTH APPL LA